3. Attach column and motor plate,
(20) to the base plate using bolts
and washers supplied, (DO NOT
OVERTIGHTEN). When viewed from
the back, ensure threaded holes in
side of the motor plate are on the
right hand side, (see Fig 1).
FIG 1
NOTE:
Before installing the motor and
collector body, (11 & 18) ensure the
two hex head screws and lock-nuts
are fitted to motor plate, (see Fig 2), It
is important that the bolt heads do
not protrude more than 20mm at this
stage, leaving them loose for
adjustment later.
FIG 2
4. Attach the motor and collector body,
(11 & 18) to the motor plate (see Fig 3),
using nuts, bolts and washers supplied,
Centralise the motor in both directions
before lightly tightening the nuts and
bolts. Adjust the bolts, ref Fig. 2 so that
the heads butt up to the collector
body, tighten the locknuts.
5. Fit the hose adapter, (37) onto the inlet
cover using the screws supplied, (see
Fig 3a). This is a safety requirement and
must be adhered to, as this part also
prevents finger access into the
impeller.