Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
POWER CONNECTION FOR MMA/TIG160 & 200
CONNECTING TO MAINS POWER
NOTE:
These welders are earthed and must only be connected to the
mains with an earth connection. DO NOT attempt to use it without
one.
• These welders will draw far too much power for a normal domestic
230V mains plug and socket and will be supplied fitted with a
32Amp, 3-pin industrial plug.
• A high current 230V mains socket or terminal must be installed by a
qualified and accredited professional electrician. A 32A socket used
with a plug conforming to IEC 60309 is recommended.
• A non-socketed mains connection also requires connection by a
qualified and accredited professional electrician. However, a
socketed connection is safer and is recommended so the welder
can be safely isolated when necessary. If directly wired to the mains,
a double pole, double throw isolator switch must be fitted.
• The welder must be connected using a circuit protected by an RCD.
• Please refer to the Specification for details of the maximum current
required by this welder.
If in any doubt, do not attempt to connect or use this welder until a
professional electrician has been consulted.