background image

2

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

INTRODUCTION

Thank you for purchasing this CLARKE Needle Scaler.

Please read all of the safety and operating instructions carefully before using 
this product. In doing so you will ensure the safety of yourself and that of others 
around you, and you can look forward to your purchase giving you long and 
satisfactory service.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 
months from the date of purchase. Please keep your receipt which will be 
required as proof of purchase. 

This guarantee is invalid if the product is found to have been abused or 
tampered with in any way, or not used for the purpose for which it was 
intended. Faulty goods should be returned to their place of purchase, no 
product can be returned to us without prior permission. 

This guarantee does not effect your statutory rights.

SPECIFICATION

Model Number

CAT51

Min. Hose Size (ID)

8mm (5/16” BSP

Max Operating Pressure

90 psi (6.2 bar)

Max Air Consumption

5 cfm (average)

Blows per minute

4500 (@ 6.2 bar)

Piston Stroke

27 mm

Air Inlet Size

1/4“BSP Female

Sound Pressure Level (LpA dB)

95.1 dB(A)

Sound Power Level (LwA dB)

106.1 dB(A)

Vibration Levels

18.2 m/s

Weight

2.8 kg

Summary of Contents for 3110565

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS GC0315 NEEDLE SCALER MODEL NO CAT51 PART NO 3110565 ...

Page 2: ... purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights...

Page 3: ...also be worn 3 Do not overreach Keep proper footing and balance at all times 4 Never use oxygen CO2 combustible gasses or any type of bottled gas as a source of power for this tool 5 Do not connect the air supply hose with your finger on the trigger 6 Do not exceed the maximum pressure for the tool of 90 psi 6 2 bar 7 Keep the air supply hose away from heat oil and sharp edges 8 Do not fit the too...

Page 4: ...esigned 19 Do not remove any labels Damaged labels should be replaced 20 This tool vibrates with use Vibration may be harmful to your hands or arms Stop using the tool if discomfort a tingling feeling or pain occurs Seek medical advice before resuming use TRANSPORT STORAGE 1 Never carry the tool by the air hose or with your finger on the trigger 2 Always disconnect from the air supply when changin...

Page 5: ... be rated at least 150 of the maximum operating pressure of the tool A typical air line layout is shown above If an automatic in line filter regulator is used it will keep the tool in good condition but should be regularly checked and topped up with oil clarke airline oil should be used and the lubricator adjusted to approx 2 drops per minute For optimum performance it is recommended that a 3 8 ID...

Page 6: ...ons Your air tool is now ready for use OPERATION FITTING THE NEEDLE HOLDER The Scaler is packed in two halves 1 The main body and hammer assembly 2 The needles with needle holder needle tube and spring The needles needle holder and spring are inserted in the Needle Tube in the manner shown in fig 1 ensuring the Needle Holder is the correct way round so that the heads of the Needles sit snugly in t...

Page 7: ...uick release coupling not supplied Ensure the operating lever is NOT depressed when connecting the air line USING THE TOOL Hold the tool with the fingers of one hand wrapped around the operating lever and bring towards the work at an angle of approx 60 70o With the airline pressure set to 90 lbf in2 6 1bar pull the operating lever and allow the needles to come into contact with the work Moving slo...

Page 8: ...ve the inlet screen filter and flush out the mechanism with gum solvent oil or an equal mixture of SAE No10 oil and paraffin Allow to dry before use 4 If the tool runs erratically or becomes inefficient and the air supply is of good quality it may be necessary to dismantle the air motor and replace worn or damaged parts You may prefer to take the tool to your CLARKE dealer if internal maintenance ...

Page 9: ...load 1 Piston parts worn 2 Worn or sticking mechanism due to lack of lubricant 1 Return to Clarke dealer for repair 2 Drip air tool lubricating oil into air inlet Allow oil to soak moving parts before using Tool runs slowly Air flows weakly from exhaust 1 Moving parts jammed with gum dirt 2 Air line regulator in closed position 3 General airflow blocked by dirt 1 Examine inlet air filter for block...

Page 10: ...5 Front Valve Block 2 O Ring 16 Piston 3 Throttle Valve 17 Barrel Sleeve 4 Spring 18 Nose 5 Gasket 19 Key 6 Valve Cap 20 Driver Retainer 7 Lever 21 Retainer Buffer 8 Pin 22 Barrel Assembly 9 Hose Adaptor 23 Retainer Clip 10 Locking Ring 24 Needle Driver 11 Alignment Shim 25 Needle 19 12 Rear Valve Block 26 Needle Holder 13 Pin 2 27 Spring 14 Valve 28 Needle Tube ...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 12: ......

Reviews: