ELECTRICAL CONNECTIONS

Before switching the product on, make sure that the voltage of your electricity supply is 
the same as that indicated on the rating plate. This product is designed to operate on 
230VAC 50Hz. Connecting it to any other power source may cause damage.

This product may be fitted with a non-rewireable plug. If it is necessary to change the 
fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or 
damaged, the plug must not be used until a suitable replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or due to 
damage, it should be cut off and a replacement fitted, following the wiring instructions 
shown below. The old plug must be disposed of safely, as insertion into a mains socket 
could cause an electrical hazard.

If the colours of the wires in the power cable of this product do not correspond 
with the markings on the terminals of your plug, proceed as follows.

• The 

Blue

 wire must be connected to the terminal marked 

N

 or 

coloured 

Black.

• The 

Brown

 wire must be connected to the terminal marked 

L

 or 

coloured 

Red.

• The 

Yellow and Green

 wire must be connected to the terminal 

marked 

or 

 or coloured 

Green

.

We strongly recommend that this machine is connected to the mains supply 
via a Residual Current Device (RCD). If in any doubt, consult a qualified 
electrician. DO NOT attempt any repairs yourself.

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE 
MAINS SUPPLY.

WARNING! THE WIRES IN THE POWER CABLE OF THIS PRODUCT 
ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL      BROWN = LIVE     YELLOW AND GREEN = 
EARTH

Plug must be BS1363/A approved.

Always fit a 13 Amp fuse.

Ensure that the outer sheath of the cable is firmly held by the clamp

Neutral

(Blue)

Live

(Brown)

Earth

(Green and Yellow)

Summary of Contents for 2320880

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 rev 7 SILENT AIR COMPRESSOR MODEL NO SHHHAIR 100 24 100 50 150 100 PART NO 2320880 2320885 2320890...

Page 2: ...months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the pu...

Page 3: ...elf against electric shock Never operate the compressor in wet or damp locations 4 NEVER over reach Keep your proper footing and balance at all times to enable better control of the compressor in unex...

Page 4: ...ressure of 10 bar or more should be used Never attempt to repair damaged hoses 8 NEVER abuse the compressor by standing on it AIRLINE HOSES 1 ALWAYS ensure that equipment or power tools used in conjun...

Page 5: ...he compressor repaired by a qualified service engineer Do not use the compressor if the On Off switch does not operate correctly 7 KEEP THE MOTOR AIR VENTS CLEAR Keep the motor vents clear and free fr...

Page 6: ...e colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The Blue wire must be connected to the terminal marked N...

Page 7: ...hat the mains voltage corresponds with that shown on the data label on the side of the compressor The ON OFF switch is in the OFF position ADDING OIL The compressor is supplied without any oil inside...

Page 8: ...right If you release air by opening the air outlet tap the motor will start automatically once the cut in pressure is reached 2 Allow the compressor to run for 10 15 seconds with the air outlet tap A...

Page 9: ...air outlet tap NOTE If the machine pumps continuously without cutting out then the compressor is too small for the application tool being used and damage may result Consult your Clarke dealer NOTE DO...

Page 10: ...e the compressor to the sink and place the free end of the small hose in the sink 4 Slowly open the vent valve 5 When the reservoir has been drained re tighten the vent valve and remove the hose DRAIN...

Page 11: ...possible that you are trying to use more air than the compressor is capable of delivering Renew oil filler air Filter plug Air leaking from the pressure switch valve when the compressor is not runnin...

Page 12: ...ons 4 Reassemble the head ensuring the sealing ring is in perfect condition and is located correctly Daily Monthly Yearly Check the oil level X Drain the water collected in the air outlet filter See D...

Page 13: ...mpressor must be completely depressurised before carrying out this procedure 1 Unscrew the cartridge from the air filter assembly 2 Unscrew and replace the small air filter STORAGE Disconnect the main...

Page 14: ...14 PARTS DIAGRAM...

Page 15: ...15 PARTS DIAGRAM SHHHAIR 100 24...

Page 16: ...16 PARTS DIAGRAM SHHHAIR 100 50...

Page 17: ...17 PARTS DIAGRAM SHHHAIR 150 100...

Page 18: ...C0517 Plug M1 C048178 Rubber Head C0522 Aluminium Washer 1 C0513 Nut with Washer C538 Plug M1 8 C0567 Nipple 1 8 C0567 Nipple 1 8 C1099 Oil Level Glass 1 2 C0568 Screw M5x6 UNI7687 C1205 O Ring 4700 C...

Page 19: ...19 DECLARATION OF CONFORMITY...

Page 20: ......

Reviews: