background image

13

CHECK THE NON RETURN VALVE

If the tank pressure decreases for no apparent reason, it is possible that the 
non-return valve is leaking. To check, ensure the tank is under pressure and the 
machine switched OFF.

1. Take off the flexible hose and check if air leaks out from the valve.

2. If so, unscrew the valve from the 

connection and disassemble it as 
shown.

3. Clean all the components with a 

dry cloth and reassemble the 
valve taking care to place the 
internal rubber disc(2) as shown.

4. Fasten the valve to the connection and join the flexible hose. If the 

leakage persists, the whole valve must be replaced.

REPLACING THE AIR OUTLET FILTER

The compressor must be completely depressurised before carrying out this 
procedure.

1. Unscrew the cartridge from the air 

filter assembly.

2. Unscrew and replace the small air 

filter.

STORAGE

Disconnect the mains plug and 
ventilate the compressor and any 
connected pneumatic tools. Store 
the compressor in a dry location. 
Always store upright.

ENVIRONMENTAL RECYCLING POLICY

By purchasing this product, the customer is taking on the obligation 
to comply with current WEEE regulations.

This means that this product must not be disposed of with general 
household waste. It must be disposed of according to the laws 

governing Waste Electrical and Electronic Equipment (WEEE) at a recognised 
disposal facility.

This product contains valuable raw materials. Metal products should be taken 
to your local civic amenity site for recycling of metal products.

Air Filter

Summary of Contents for 2320880

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 rev 7 SILENT AIR COMPRESSOR MODEL NO SHHHAIR 100 24 100 50 150 100 PART NO 2320880 2320885 2320890...

Page 2: ...months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the pu...

Page 3: ...elf against electric shock Never operate the compressor in wet or damp locations 4 NEVER over reach Keep your proper footing and balance at all times to enable better control of the compressor in unex...

Page 4: ...ressure of 10 bar or more should be used Never attempt to repair damaged hoses 8 NEVER abuse the compressor by standing on it AIRLINE HOSES 1 ALWAYS ensure that equipment or power tools used in conjun...

Page 5: ...he compressor repaired by a qualified service engineer Do not use the compressor if the On Off switch does not operate correctly 7 KEEP THE MOTOR AIR VENTS CLEAR Keep the motor vents clear and free fr...

Page 6: ...e colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The Blue wire must be connected to the terminal marked N...

Page 7: ...hat the mains voltage corresponds with that shown on the data label on the side of the compressor The ON OFF switch is in the OFF position ADDING OIL The compressor is supplied without any oil inside...

Page 8: ...right If you release air by opening the air outlet tap the motor will start automatically once the cut in pressure is reached 2 Allow the compressor to run for 10 15 seconds with the air outlet tap A...

Page 9: ...air outlet tap NOTE If the machine pumps continuously without cutting out then the compressor is too small for the application tool being used and damage may result Consult your Clarke dealer NOTE DO...

Page 10: ...e the compressor to the sink and place the free end of the small hose in the sink 4 Slowly open the vent valve 5 When the reservoir has been drained re tighten the vent valve and remove the hose DRAIN...

Page 11: ...possible that you are trying to use more air than the compressor is capable of delivering Renew oil filler air Filter plug Air leaking from the pressure switch valve when the compressor is not runnin...

Page 12: ...ons 4 Reassemble the head ensuring the sealing ring is in perfect condition and is located correctly Daily Monthly Yearly Check the oil level X Drain the water collected in the air outlet filter See D...

Page 13: ...mpressor must be completely depressurised before carrying out this procedure 1 Unscrew the cartridge from the air filter assembly 2 Unscrew and replace the small air filter STORAGE Disconnect the main...

Page 14: ...14 PARTS DIAGRAM...

Page 15: ...15 PARTS DIAGRAM SHHHAIR 100 24...

Page 16: ...16 PARTS DIAGRAM SHHHAIR 100 50...

Page 17: ...17 PARTS DIAGRAM SHHHAIR 150 100...

Page 18: ...C0517 Plug M1 C048178 Rubber Head C0522 Aluminium Washer 1 C0513 Nut with Washer C538 Plug M1 8 C0567 Nipple 1 8 C0567 Nipple 1 8 C1099 Oil Level Glass 1 2 C0568 Screw M5x6 UNI7687 C1205 O Ring 4700 C...

Page 19: ...19 DECLARATION OF CONFORMITY...

Page 20: ......

Reviews: