Clarke 2320870 Operation & Maintenance Instructions Manual Download Page 17

17

COMPONENT PARTS LIST

NO

DESCRIPTION

C0037

Screw TCEI 6X20

C0051

Rylsan Hose ?4/6

C0106

Spacer T21

C0077

Swivel Connector M1/4

C0109

Capacitor Bracket

C0082

Pressure 1 WAY

C0111

Overload Protector T2134A 
(230V)

C0083

Connection M 1/4  L=80

C0112

Start Relay T21 (230V)

C0089

Nipple 1/4" L=95

C0113

Screw

C0091

Electric Cable MM 500

C3078

Cylinder Gasket

C0348

"T" Connection F-F-F 1/4"

C3076

Valve Plate with Valve

C0133

240v Cable 3X0.75  L.2500

C0117

Head Gasket

C2376

Filter Regulator

C0118

Oil Plug 3/8+O Ring

C0297

Air Hose

C0126

Rubber Grommet T21

C0301

Exhaust Valve

C0220

Kit Terminal Box T21 (230V)

C0334

"Distribution Frame "L" M-F 1/8 
CH13"

C3077

Intake Valve

C0354

Draincock M 1/4 90

n/a

n/a

C045624 Tank

C048178 Rubber Head

C0517

Plug M1"

C0513

Nut with Washer

C0522

Aluminium Washer 1"

C0567

Nipple 1/8"

C0567

Nipple 1/8"

C1099

"Oil Level Glass 1/2"

C0573

Hand Grip

C1205

O Ring 4700

C0582

Black Rubber Support D20

C1235

Valve Plate Set (until s/n 17s)

C1712

Gauge D40 1/8 0-12 BAR

C1794

Kit Intake Filter

C1728

Hose

C2083

Capacitor

C1965a

Pressure Relief Valve

C0046

Non Return Valve M-F 1/8""

C2369

Outlet tap

C0047

Quick Coupling M5X?6

C0133

240V Cable 3x0.75  L.2500

C3079

Valve Plate Set (from s/n 18E)

C0297

Air Hose

Summary of Contents for 2320870

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 rev 10 SILENT AIR COMPRESSOR MODEL NO SHHHAIR 50 9 PART NO 2320870...

Page 2: ...nteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused...

Page 3: ...elf against electric shock Never operate the compressor in wet or damp locations 4 NEVER over reach Keep your proper footing and balance at all times to enable better control of the compressor in unex...

Page 4: ...ressure of 10 bar or more should be used Never attempt to repair damaged hoses 8 NEVER abuse the compressor by standing on it AIRLINE HOSES 1 ALWAYS ensure that equipment or power tools used in conjun...

Page 5: ...he compressor repaired by a qualified service engineer Do not use the compressor if the On Off switch does not operate correctly 7 KEEP THE MOTOR AIR VENTS CLEAR Keep the motor vents clear and free fr...

Page 6: ...e colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The Blue wire must be connected to the terminal marked N...

Page 7: ...n on the data label on the side of the compressor The ON OFF switch is in the OFF position Remove any transit caps from the air inlets and replace them with the air inlet filters supplied ADDING OIL T...

Page 8: ...pressor turn the ON OFF switch to the I ON position the motor should start immediately NOTE If the motor fails to start immediately the air receiver may already be full of air Check the tank pressure...

Page 9: ...n on the outlet gauge D To lock the pressure regulator knob push the pressure regulator knob down until it clicks into place IMPORTANT Always refer to the accessory manufacturers recommendations for o...

Page 10: ...tach the small hose supplied to the vent valve as shown 3 Take the compressor to the sink and place the free end of the small hose in the sink 4 Slowly open the vent valve 5 When the reservoir has bee...

Page 11: ...possible that you are trying to use more air than the compressor is capable of delivering Renew oil filler air Filter plug Air leaking from the pressure switch valve when the compressor is not runnin...

Page 12: ...ons 4 Reassemble the head ensuring the sealing ring is in perfect condition and is located correctly Daily Monthly Yearly Check the oil level X Drain the water collected in the air outlet filter See D...

Page 13: ...y cloth and reassemble the valve taking care to place the internal rubber disc 2 as shown 4 Fasten the valve to the connection and join the flexible hose If the leakage persists the whole valve must b...

Page 14: ...ns that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal...

Page 15: ...15 PARTS DIAGRAM...

Page 16: ...16 PARTS DIAGRAM...

Page 17: ...C0297 Air Hose C0126 Rubber Grommet T21 C0301 Exhaust Valve C0220 Kit Terminal Box T21 230V C0334 Distribution Frame L M F 1 8 CH13 C3077 Intake Valve C0354 Draincock M 1 4 90 n a n a C045624 Tank C0...

Page 18: ...18 WIRING DIAGRAM FLOW CHART...

Page 19: ...19 DECLARATION OF CONFORMITY...

Page 20: ......

Reviews: