10
3. Before transporting your
compressor or when leaving
overnight, expel all air from the
receiver by opening the vent
valve.
DRAINING THE RESERVOIR
1. Pressurise the reservoir slightly and
then turn the compressor off.
2. Attach the small hose supplied to
the vent valve as shown.
3. Take the compressor to the sink
and place the free end of the
small hose in the sink.
4. Slowly open the vent valve.
5. When the reservoir has been
drained, re-tighten the vent valve and remove the hose.
DRAINING THE AIR OUTLET FILTER
1. Drain any liquid that may have
accumulated in the air filter
chamber, by first twisting and then
pushing the valve (E) upwards.
Valve (E)
Summary of Contents for 2320870
Page 15: ...15 PARTS DIAGRAM...
Page 16: ...16 PARTS DIAGRAM...
Page 18: ...18 WIRING DIAGRAM FLOW CHART...
Page 19: ...19 DECLARATION OF CONFORMITY...
Page 20: ......