9
SWITCHING THE AIR COMPRESSOR ON
1. To start the compressor, turn the
ON/OFF switch to the ‘I’ (ON)
position - the motor should start
immediately.
NOTE:
If the motor fails to start
immediately, the air
receiver may already be
full of air. Check the tank
pressure gauge (shown
on the right). If you
release air, by opening
the air outlet tap, the
motor will start
automatically once the
cut-in pressure is
reached.
2. Allow the compressor to run for 10
- 15 seconds, with the air outlet
tap, (A) open.
• This will distribute the lubricating
oil.
3. Close the outlet tap and connect
a suitable air hose to the filter/
regulator outlet (B). Connect the
other end to the equipment to be
used.
4. Check the safety valve by pulling
on the end cap shown.
•
Pliers will be needed to grip the
end cap and pull against the
spring. Air should hiss out when the
valve is pulled.