13
Parts & Service: 0871 410 1270 / e-mail: [email protected] or [email protected]
REPLACING THE OIL
After the first 100 hours use, replace
the oil using SAE30 compressor oil.
Then replace the oil after every 500
hours of operation or every 6 months.
To empty the oil from the machine,
remove the oil drain plug from the
crankcase.
CHECKING THE NON-RETURN
VALVE
If the reservoir pressure decreases for no apparent reason it is possible that the
non-return valve is leaking. To check this:
1. Make sure that the reservoir is not
under pressure and the
compressor is switched OFF.
2. Examine the non-return valve,
and replace the gasket and valve
if necessary.