Jumper Selections
Parking Light Polarity. Selects the polarity (+/-) for the output of the on-board Parking Light
relay.
Pin 1 + Pin 2 = positive
Pin 2 + Pin 3 = negative
Auto Rearm. When the jumper is
off the system will automatically rearm if no other activity is
detected within one minute of Remote Disarming.
One minute after Remote Disarming, the system will alert you with a 10 second series of
chirps, then arm. (If the Passive Door Locking feature is selected during the installation, the
system will also relock the doors.)
Any of the following will cancel Automatic System Rearming:
• Turn on the ignition.
• Open the Trunk or Hood.
• Activate Auxiliary Function 1 or 2.
Automatic System Rearming is independent of Passive Arming and only takes place if the
system was Armed (actively or passively) for at least 20 seconds and then Disarmed by the
Remote Transmitter.
Horn Honk / Alarming Output. Selects between a pulsed output to drive a horn relay or a
constant output to drive air horns or additional sirens.
Auxiliary 2 Output. Selects between Momentary or Latched output for Aux. 2.
When the jumper is
off, Momentary operation is selected. The system will provide an
output for as long as the Transmitter button is held.
When the jumper is
on, Latched operation is selected. The system will provide an output
that turns on when the transmitter button is pressed and turns off when the transmitter
button is pressed again.
Sensor Defeat with Auxiliary Function 1 (Dedicated Remote Start Mode). When the jumper
is on, the sytem will ignore the Shock Sensor and Optional Sensor when the Auxiliary
Function 1 is activated. The system will continue to ignore these sensors until the next time
the system is armed.
Ignore Delayed Dome Light. For use with vehicles equipped with a timed dome light circuit that
stays on after door has been closed. When the jumper is
on, the system will ignore the
dome light circuit during arming to prevent the system from responding with an open zone
indication each time the system is armed.
Passive Door Locking. When the jumper is
on, the system will automatically lock the doors with
Auto Rearm and Passive Arming.
Door Lock / Unlock Pulse Width. Selects between a 1-second and a 4-second output for door
locking and unlocking. When the jumper is on, the door lock/unlock output will activate for
4 seconds for interfacing into vehicles equipped with vacuum door locking systems.
Jumper Settings