4. User Selectable Programming Options

The Ungo MS2106 features a user selectable programming table allowing simple
adjustments to match the user’s preferences.    

User Programming Options Table

4.1 User Programmable Options

1.

Arming Mode:

Selects whether or not the system will automatically Arm when

ignition is turned off.

2.

Auto Rearming:

Selects whether or not the security system will rearm if no

activity is detected after Remote Disarming. (If Passive Door Locking feature
was selected during installation, the system will also relock the doors.)
Automatic Rearming only takes place if the system was Armed (actively or
passively) for at least 10 seconds and then remotely disarmed.

3.

Arming Chirps:

Selects whether or not the security system will chirp when arm

and disarmed.

4.

Ignition Controlled Door Locking:

Selects whether or not the doors will lock

when the ignition is turned On. Ignition Controlled Door Locks will automatically
lock the doors 10 seconds after the ignition is turned On.  To prevent the keys
from being locked inside the vehicle; the security system will not lock the doors
if any of the doors is open when the ignition is turned On.

5.

Ignition Controlled Door Unlocking:

Selects whether or not the security

system the doors will unlock when the ignition is turned Off. Ignition Controlled
Door Unlocking can be configured to unlock all the doors or driver's door only.

6.

Override Code Programming:

Selects the number of times the Valet button

must be depressed to override the system. The Override Code can be any
number between 1 and 15.  (Default setting is 1)

1.

Arming Mode

Active

Passive

2.

Auto Rearm 

On

Off

3.

Arming Chirps

Normal

Silent

4.

Ignition Controlled Door Locking

On

Off

5.

Ignition Controlled Door Unlocking

All Doors

Driver’s Door 

Off

6.

Override Code Programming

Code Set

7.

Remote Start in Valet Mode

Enabled

Disabled

8.

Automatic Starting

Disabled

Temperature Start

Voltage Start

Steps 7 & 8 are reserved for use with Ungo-Net Start Module.

Feature

Button 1 (default) Button 2

Button 3

MS2106 owner 7-14.qxd  7/14/2003  1:42 PM  Page 11

Summary of Contents for UNGO MS2106

Page 1: ...MS2106 ...

Page 2: ...o Rearm Feature 4 3 6 Chirp Delete 4 3 7 Ignition Controlled Door Locks 4 3 8 Remote Panic 5 3 9 Emergency Override 5 3 10 Valet Mode 5 3 11 Optional Trunk Release 6 3 12 Optional Trunk Disarm Feature 6 3 13 Remote Sensor Bypass 6 3 14 Programming Remote Transmitters 6 3 16 Transmitter Operation 7 3 17 Status Indicator LED Functions 7 3 18 Siren Chirp Status 7 5 User Selectable Programming Options...

Page 3: ...system will also inform the user of any defective zones or sensors that may be causing the system to function improperly Protect both you and the contents of your vehicle with features such as panic mode dome light illumination and ignition controlled door locking Optional Features Note Some features may require additional parts and labor and may not be appropriate for certain vehicles Consult you...

Page 4: ...needs of the operator The Arm and Disarm buttons can be consolidated into the one button with the remaining buttons controlling assignable features Capitalizing on Ungo Net an optional LCD FM transmitter kit can be added to the security system part FMKIT This transmitter features 2 way communication via FM frequency for increased transmitting range and operation With audible and visual confirmatio...

Page 5: ...vel Shift button is pressed a new level of commands are accessed up to a maximum of four levels Level Shift three times Note pages 3 and 4 are reserved for channel expansion modules or multi car operation See your Authorized Ungo Dealer for details Optional feature 3 2 Battery Replacement Your Ungo Remote Transmitter uses a 12 volt alkaline battery type 23A which will need to be replaced from time...

Page 6: ...ws the system to arm automatically The remote transmitter still can be used to arm the system at any time This option is user programmable see User Accessible Programming Options To arm the alarm system passively 1 Turn the ignition Off 2 Exit the vehicle and close all the doors The LED will begin flashing rapidly to indicate the system is preparing to arm The siren will chirp 30 seconds after the...

Page 7: ...arning will not be cancelled when the system is Armed or Disarmed silently 3 7 Optional Driver s Door Priority Unlock The optional Driver s Door Priority Unlock feature provides a higher level of personal safety by unlocking only the driver s door upon disarming Once disarmed pressing the disarm button again will unlock all doors This optional feature may require addtional parts and labor consult ...

Page 8: ...n 3 Press the Override switch a number of times equal to the disarm code and continue holding for 10 seconds on the last press If the default code setting has not been changed press and hold the override switch for 10 seconds to disarm to system The system will disarm The siren will stop sounding Starter disable will turn Off 4 You can now start and drive the car 5 If the disarm code is not entere...

Page 9: ...ating the system is out of Valet mode 3 13 Optional Trunk Release Press the Trunk button for approximately 3 seconds to open the trunk This optional feature may require addtional parts and labor consult your Authorized Ungo dealer for more information 3 14 Optional Trunk Disarm Feature The trunk disarm feature allows the alarm to disarm automatically when the Trunk button is used to activate the o...

Page 10: ...he siren will chirp once 4 Press the Lock button on the transmitter again The siren will chirp twice 5 Repeat steps 3 and 4 for each additional transmitter 6 Turn OFF the ignition when transmitter programming is complete The siren will chirp 3 times ...

Page 11: ...Door Locks will automatically lock the doors 10 seconds after the ignition is turned On To prevent the keys from being locked inside the vehicle the security system will not lock the doors if any of the doors is open when the ignition is turned On 5 Ignition Controlled Door Unlocking Selects whether or not the security system the doors will unlock when the ignition is turned Off Ignition Controlle...

Page 12: ...rogramming has been entered 3 Press the Valet Override button the number of times equal to the Option to be changed The siren will chirp each time the Valet Override button is pressed 4 Within 5 seconds press the transmitter button corresponding to the desired operating mode for that Option The siren will chirp a number of times equal to the transmitter button pressed 5 When finished turn the igni...

Page 13: ...nd not in Valet mode FUNCTION System is disarmed in Active mode System is Armed Passive arming indication and auto rearm System was triggered Valet mode On for 10 seconds shock sensor trigger has not yet armed Door or hood trunk is open 3 18 Siren Chirp Status CHIRPS 1 Chirp 2 Chirps 3 Chirps 4 Chirps 5 Chirps 2 Chirps when the ignition is turned Off FUNCTION System Armed System Disarmed System Di...

Page 14: ...oration under this Warranty shall be limited to the repair or replacement of the product at the sole discretion of Clarion Corporation If it becomes necessary to send the product or any defective part to Clarion Corporation the product must be shipped in its original carton or equivalent carton fully insured with shipping charges prepaid Clarion Corporation will not assume any responsibility for a...

Page 15: ...15 7 INSTALLATION INFORMATION Date of Installation Installation Facility Facility Address Facility Phone Number Location of Valet Override NOTES ...

Page 16: ...Clarion Corporation of America 661 W Redondo Beach Blvd Gardena CA 90247 www clarion com 97 MS2106 10 Rev 1 8 03 Ungo Security Corporation Gardena CA ...

Reviews: