background image

01

Enrollment

 

With the translator, sensors are enrolled into the panel via RF transmission.  Once 

enrolled, the zones are configured in the panel the same way as Clare zones.  It is 

important to follow enrollment instructions carefully, and execute the steps in order, so 

that devices are enrolled properly.  Before enrollment, the panel will first need to be set 

to the proper translator protocol and save the panel settings. This is set via the dealer 

portal or installer app. 

  Enrolling GE Devices

 

 

•  Place panel in sensor enrollment mode. 

 

•  Activate particular GE sensor as follows: 

 

o  

DWS:

 Open the cover of the sensor

 

 

o  

PIR & Glass break:

 Open the cover of the sensor 

 

o  

Key fobs:

 Press the Lock and Unlock buttons simultaneously for 3 seconds 

 

o  

Panic:

 Press the panic button 

 

Enrolling DSC Devices 

 

•  Place panel in sensor enrollment mode. 

 

•  Activate particular DSC sensor as follows: 

 

o  

DWS:

 Open and close the cover of the sensor

 

 

o  

PIR & Glass break:

 Open and close the cover of the sensor 

 

o  

Key fobs:

 Press the panic button (lower right) 

 

o  

Panic:

 Press the panic button

 

Enrolling DSC Devices 

 

•  Remove batteries on all PIR motion detectors 

 

•  Place panel in sensor enrollment mode. 

 

•  NOTE: Honeywell sensor types must be enrolled in the following order. 

 

    Activate particular Honeywell sensor as follows: 

 

o  

PIR with Tamper:

 Press and hold tamper button and insert battery

 

 

o  

PIR without Tamper:

 Insert battery 

 

o  

DWS:

 Cycle the door or window contact three times, either open-close-open or 

 

    close-open-close.  Allow no more than 3 seconds between actions 

 

o  

Panic:

 Open panic and remove the battery. Press and hold the panic button and 

 

    insert battery with button pressed. Release button within 3 seconds 

 

Enrolling Napco Devices 

 

Place panel in sensor enrollment mode. 

 

Activate particular Napco sensor as follows:

 

 

o  

DWS:

 Open and close the cover of the sensor

 

 

o  

PIR & Glass break:

 Open and close the cover of the sensor 

 

o  

Key fobs:

 Press the AUX2 (Panic) button 

 

o  

Panic:

 Napco Panic is not supported by the translator

01

 

Enrolling 2GIG Devices

 

 

•  Place panel in sensor enrollment mode. 

 

•  Activate particular 2GIG sensor as follows: 

 

o  

DWS:

 Cycle the door or window contact three times, either open-close-open or 

 

    close-open-close. Allow 2 or 3 seconds between actions.

 

 

o  

PIR:

 Press and hold tamper button and insert battery 

 

o  

Glassbreaks:

 Open and closer cover of sensor 

 

o  

Key fobs:

 Press and hold Arm Away and DIsarm buttons simultaneosly 

 

o  

Panic:

 Press the panic button 

 

Testing 

 

•  Verify in the web portal or installer app that the device shown, device type, and 

 

    setting are correct for each zone. 

 

•  Verify that the correct number of zones were enrolled into the panel.  

 

•  Test each zone to verify proper operation. 

 

Z-Wave

   

Z-Wave devices can be controlled via the Interactive function.

 

Picture

 

Green LED:

ON - 

When panel is AC powered

OFF - 

When panel does not have 

AC power

Flickers -

 With Each sensor 

packet received

Red LED:

Normally off, flashes with each 
Zwave message received from 
pane

l

Reviews: