background image

 

4 / 7 

 

DOC ID 

– 1990 • Rev 01 (

47-00014 Rev A)

 

 

Verify adequate RF signal strength at the panel 
before permanently mounting. 

B.  Connect the power supply to the W2WL using the supplied 

barrel connector. 

 

Rotate the barrel plug down to the right so the wires 
exit the enclosure through the strain relief area.  

 

Ensure the backup battery connector is plugged into 
the translator.  

 

Do not connect to a receptacle controlled by a switch. 

 

In the United States, the transformer must be secured 
to an outlet. 

 

In Canada, the transformer must NOT be secured to 
the outlet. 

2.  Translator configuration 

A.  Set the 

PANEL SELECT

 knob to ClareOne. 

B.  Select the brand of sensors that the translator must 

listen to using the 

SENSOR SELECT

 knob.  

C.  Sensor Configuration: The translator must learn the 

sensors that are to be translated or repeated.  

1.  Press and release the 

CONFIGURE

 button to 

enter translator configuration mode. The 
yellow LED will turn on when translator 
configuration mode is entered.  

2.  Tamper or trip all sensors to be included in 

the system. The translator beeps for each 
sensor that is included in the system.  

3.  Press 

CONFIGURE

 button to exit translator 

configuration mode. The yellow LED will turn 
off when the translator mode is exited.  

3.  Panel Enrollment:  

A. 

Access the ClareOne panel’s Sensor Settings 
(Settings > Installer Settings > Sensor Management > 
Add Sensors), then select “Wireless to Wireless” as 
the device type. For detailed programming 
instructions, please refer to the ClareOne Wireless 
Security and Smart Home Panel User Manual (DOC 
ID 1871). 

B.  Trip the cover tamper to enroll the W2WL into the 

panel. 

-or- 

Enter ID into panel. The 

W2WL’s base ID is printed 

on the bar code label. 

C.  Access  the  ClareOne  panel

’s  Sensor  Settings,  then 

select  the  type  of  sensor  to  add.  Trip  one  of  the 
repeated  or  translated  sensors  to  enroll  it  with  the 
panel.  

D.  Repeat step C for each repeated or translated sensor.  

 

 

4.  Finish 

A.  With the translator cover open, perform a panel 

sensor test.  

1.  When the translator cover is open, the translator 

will only send sensor transmissions to the panel if 
the received sensor transmissions have enough 
signal margin to be reliably received by the 
translator.  

2.  Closing the translator cover exits the translator 

sensor test mode. When the translator is not in 
sensor test mode, all received sensor 
transmissions are sent to the panel.  

3.  Translator sensor test mode is locked out 24 

hours after power up. To re-enable sensor test 
mode, the translator must be power-cycled by 
removing both 12VDC input power and backup 
batter for at least 5 seconds.  

B.  Close the cover. Test and verify proper operation at 

the panel. Ensure all sensor alarms are reported 
properly to the central station.  

C.  Translator locking.  

CAUTION:

 Manual W2WL locking cannot be undone.  

Locking the translator locks all translator configuration 
settings and provides takeover protection. 

Note: 

If the lock wire is not cut, the translator 

automatically locks after 30 days of continuous operation. 
The effects are the same as manual locking; however, the 
automatic lock can be reset by power cycling the translator 
while the cover is open. 

CAUTION:

 Manual W2WL locking cannot be undone.  

1.  Ensure all sensors are functioning as desired. 

2.  Carefully review the effects of manual translator 

locking before proceeding: 

 

The translator cannot be factory defaulted 
once the lock wire is cut.  

 

Existing sensor configurations cannot be 
changed. However, new sensors may be 
configured.  

 

Panel selection cannot be changed. 

 

Sensor selection cannot be changed. 

 

Manual W2WL LOCKING CANNOT BE 
UNDONE. 

3.  Open the translator cover and cut the lock wire. 

The green and red LEDs flash and the sounder 
beeps to confirm. 

Note: 

If the lock wire is not cut, the translator will 

automatically lock after 30 days of continuous 
operation. The effects are the same as manual 
locking; however the automatic lock can be reset 
by power cycling translator while the cover is 
open.  

Summary of Contents for ClareOne CLR-C1-W2WL

Page 1: ...o Wireless Translator Repeater Installation Sheet Last modified 12 23 20 Model number CLR C1 W2WL Features Selectable wireless sensor compatibility Translator or repeater operation Rechargeable backup...

Page 2: ...n mode The amber LED will illuminate and stay on 2 Tamper or trip all sensors that need to be repeated by the W2WL The W2WL will beep each time a sensor is enrolled Note Sensors with multiple inputs m...

Page 3: ...s at the panel C Cut the lock wire to lock the translator for more information on locking refer to the Advanced Setup section below CAUTION Cutting the lock wire prevents the removal of sensors from t...

Page 4: ...ach repeated or translated sensor 4 Finish A With the translator cover open perform a panel sensor test 1 When the translator cover is open the translator will only send sensor transmissions to the pa...

Page 5: ...ault conditions 12VDC input overvoltage fault Continually flashes and beeps on the green LED and speaker 12VDC input removed fault Green LED turns off and the speaker makes a long beep Factory default...

Page 6: ...provisions of Directive 1999 5 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this p...

Page 7: ...Controls LLC 7519 Pennsylvania Ave Suite 104 Sarasota FL 34243 General 941 328 3991 Fax 941 870 9646 www clarecontrols com Integrator Dealer Support 941 404 1072 claresupport clarecontrols com Homeow...

Reviews: