8
Revised 08/09
V SERIES
Cartridge Dust Collector
4. Install a new filter element by sliding it into the filter
housing with the gasket of the after-filter leading.
5. Replace the exhaust screen and secure the four
draw latches to seal the filter.
6.4 SERVICING DIRECT DRIVE BLOWER
To gain access to the direct drive motor/blower you
must first remove the discharge air plenum as shown in
Figure 7.
NOTE:
The blower rotation should be clockwise when
looking at the motor from the discharge side of
the cabinet.
See the troubleshooting guide in Section 8 of this
manual for clues on motor/blower problems.
7. ELECTRICAL
Tables 1 and 2 provide a listing of V Series model
numbers and their corresponding voltage, motor
horsepower and full load amperage draw.
Please complete the provided blanks on the inside
cover of this manual. This will help you to identify your
unit when dealing directly with United Air Specialists or
your local UAS representative.
7.1 UNIT CONTROL (ON/OFF)
All units will have the blower controlled from the unit
control panel (refer to Figure 6). A black ON/OFF rocker
switch is provided to start/stop the blower.
7.2 CLEANING CONTROLS (ON/OFF)
Section 4.4.1 of this manual clearly outlines the
available settings and operation of the pulse cleaning
system.
Control of the reverse pulse cleaning system is by a
rocker switch on the unit control panel (refer to Figure
6). The pulse cleaning system operates independent of
the blower. This provides for off-line cleaning.
NOTE:
Compressed air must be connected prior to
engaging cleaning system to prevent damage to
diaphragm valves.
Electrical Schematics
An electrical schematic was included with your unit in
this packet. Please secure the drawing to this manual
for future reference. A copy of the appropriate wiring
diagram is also affixed on the inside of the control
panel.