Tap LEDs
(Touch-Free excluded)
Red Hot Water LED
On all the time
This indicates that the hot water is ready.
Flashing slowly
This indicates that the temperature of hot water is not within the set
range.
When the hot water is at the set temperature, the light will stop
fl ashing. This could take several minutes.
The fl ashing light will typically occur after switching on, during heavy
usage or coming out of sleep mode.
Safety sensor calibration
1. Shield the HydroTap from any
direct sun light e.g. using a dark
cloth.
2. Bring the unit in normal operating
mode.
3. Turn the power OFF.
4. Pull both tap levers to the forward
position.
5. Turn ON the power.
6. The unit will calibrate the safety
switch automatically.
7. Return the levers to the neutral
position.
Light intensity varies from site to site, therefore it is recommended
that a re-calibration be performed at the time of the installation.
All direct natural sun light must be shaded from the HydroTap,
during the calibration. This can be achieved by closing any nearby
curtains, blinds and so on.
Pull both levers
forward
Safety Sensor Calibration (Classic only)
Safety
sensor