background image

P.12

P.13

10. How to Use

10. How to Use

As soon as you open the hot water tap, the 

instantaneous water heater switches on 

automatically. When the tap is closed, the appliance 

automatically switches off.

Temperature setting

You can set the required temperature gradually to a 

lower or higher value with the arrow keys   and  .
The temperature changes by 1°C, in the convenience 

zone between 35°C and 42°C by 0.5°C, if key is 

pressed shortly one time. Pressing a key for a longer 

time changes the temperature continuously.

Note: If temperature is set below 20°C with arrow 

key   the display shows “- -” and the appliance 

switches off the heating function.
Note: If the water heater supplies a shower and is 

connected to a remote control system, the maximum 

temperature was reduced during initial operation. 

This limitation cannot be exceeded.

Programme buttons

The two programme buttons allow to quickly select 

the preset temperature. When pressing a programme 

key, the preset temperature is selected and displayed. 

The factory setting for programme    is 35°C and for 

programme   it is 48°C. You can assign your own 

settings for the programme keys:
• Prolonged pressing of the programme key stores 

the previously selected temperature. The display 

changes from “P1” or “P2” to the newly stored 

temperature value. This newly set temperature 

is now available to you each time you press the 

corresponding program key.

MADE IN GERMANY

Set temperature

1

–1 °C

+1 °C

Select preset temperature

A1

A2

B1

B2

Store temperature

2

Press

 3 sec

Display of new value

(e.g. 43 °C)

Set required 

temperature

(e.g. 43 °C)

4

3

1

Convenience zone 35.0..42.0 °C 

1

–0.5 °C

+0.5 °C

Temperature limitation

This instantaneous water heater is equipped with an 

optional temperature limiting function. This scalding 

protection is deactivated in the factory setting.
• Switch on: Select the limit temperature, then press 

 and   simultaneously for at least 3 sec. The 

display briefly confirms the activation by “HI“.

• Switch off: press program key   and   

simultaneously for at least 3 sec. The display briefly 

confirms the deactivation by “- -“.

Note: By activation of the temperature limit also the 

programme keys are affected. Therefore, the fixed 

values of the programme keys must be checked 

after changing the temperature limitation.

Reset to factory setting

All factory settings can be recalled:
• Press   and   and simultaneously. The display now 

counts backwards from “10“ to “00“ in second 

intervals. The appliance is reset at value “00“ - if 

you stop pressing the keys earlier, you will cancel 

the process.

+

Reset 

1

Press + hold!

Reset completed

3

2

+

Press

 3 sec

1

2

Scalding protection off

Confirmation

of deactivation

3

Confirmation

of activation

Scalding protection on

+

Press

 3 sec

1

2

Summary of Contents for German pool CEX13

Page 1: ...instructions and warranty information carefully before use and keep them handy for future reference O P E R A T I N G I N S T R U C T I O N S WH CEX13 M 16 3 Printed in Germany MADE IN GERMANY A EU E...

Page 2: ...on 06 7 Installation 07 Mounting the appliance 08 Installing the appliance 08 8 Electrical connection 09 Wiring diagram 09 Structural prerequisites 09 Electrical installation to a permanent connection...

Page 3: ...who is responsible for the installation of the appliance Operation manuals are for the end user Thelatestversionoftheinstructionscanbefoundonlineatwww germanpool com Model CEX13 ELECTRONIC MPS Energy...

Page 4: ...istance between the instantaneous water heater and the tapping point should be as small as possible For maintenance work a shut off valve should be installed in the supply line The appliance must be a...

Page 5: ...le disconnecting device e g via fuses with a contact opening width of at least 3 mm per pole should be provided at the installation end To protect the appliance a fuse element must be fitted with a tr...

Page 6: ...set power rating on the rating plate 6 Open the hot water tap Check the function of the appliance 7 After having set the maximum allowable power rating the heating element will be activated after app...

Page 7: ...P2 to the newly stored temperature value This newly set temperature is now available to you each time you press the corresponding program key MADE IN GERMANY Set temperature 1 1 C 1 C Select preset t...

Page 8: ...lowing repair work the appliance must be re vented before it is used again 1 Disconnect the instantaneous water heater from the mains e g via deactivating the fuses 2 Unscrew the jet regulator on the...

Page 9: ...andard display Individual menu items as follows FL Flow Indication of current flow rate given in l min Po Power Indication of current power consumption kW t1 Temp in Indication of inlet temperature C...

Page 10: ...ress 3 sec 1 2 Enter service menu 2 8 4 7 5 3 6 9 1 Display flashes Press 2 sec MADE IN GERMANY Problem Cause Solution Water stays cold digital display does not light up Master fuse tripped Renew or a...

Page 11: ...P 21 1 21 2 22 3 22 4 23 5 24 6 24 7 25 26 26 8 27 27 27 27 9 28 28 29 29 29 10 30 30 30 31 31 32 ECO 32 32 32 33 33 11 33 12 34 13 36 37 1...

Page 12: ...16A 13 5kW 20A 3 PE 380 415V AC 1 5mm2 2 5mm2 t 33K 4 8 5 8 1 0 3l 1 2MPa 10 bar IES 15 1100 cm 90 9mS m 70 2 0 5 0l min 2 0 2bar 2 5l min 1 3bar 9 0l min 3 20 60 G 2 7kg VDE I IP25 812 2013 1 2 3 4 6...

Page 13: ...P 24 P 25 6 6 5 312 100 177 108 37 mm 7 EN 806 IP25 DIN 16893 2 15 1100 cm MADE IN GERMANY MADE IN GERMANY 177 294 100 850 1200 1950 mm 0 MADE IN GERMANY...

Page 14: ...P 26 P 27 80 70 140 7 57 153 84 41 26 28 96 140 8 7 1 2 3 A A 4 B B 5 6 6mm 5mm 7 1 1 2 2 2 1 4 5 3 VDE 0100 6 mm2 3mm 1 2 3 4 5 6 1 2 3 4 5...

Page 15: ...P 28 P 29 MADE IN GERMANY 9 55 55 55 EN60900 88 1 2 3 1 2 4 1 2 1 2 3 9 11kW 400V 13 5kW DIN VDE 0100 1 2 88 3 11 13kW 4 5 6 7 10 8 9...

Page 16: ...P 30 P 31 10 3 HI 3 _ _ 10 00 00 1 3 2 3 1 2 3 3 1 2 10 1 35 42 0 5 20 _ _ 35 48 P1 P2 MADE IN GERMANY 1 3 43 43 35 0 42 0 C 1 1 C 1 C A1 A2 B1 B2 2 4 3 1 0 5 C 0 5 C...

Page 17: ...P 32 P 33 10 1 2 3 4 5 10 11 10 ECO ECO...

Page 18: ...P 34 P 35 12 nr Ch rS 10 100 tL IIC 12 2 FL FL Po kW t1 t2 CA 40 60 PL kW Er 1 10 0 9 0 1 LL 0 1 2 1 3 2 1 2 4 3 1 2 3 4 2 2 8 4 7 5 3 6 9 1...

Page 19: ...P 36 P 37 1 2 3 1 3 43 43 35 0 42 0 C 1 3 2 1 3 2 1 2 1 C 1 C A1 A2 B1 B2 2 4 3 1 0 5 C 0 5 C 3 1 2 2 8 4 7 5 3 6 9 1 MADE IN GERMANY 13 CEX Er Er MAX MAX sun MADE IN GERMANY...

Page 20: ...part 5 This warranty will be void if there is any transfer of ownership from the original purchaser 1 2 3 4 5 Serial No Purchased From Invoice No Purchase Date Model No Please fill out the form below...

Page 21: ...n Kowloon Hong Kong 3 F Takshun Plaza Nanguo East Road Shunde Foshan Guangdong 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 852 2773 2888 Fax 852 2765 8215 Tel 86 757...

Reviews: