clage E-comfort DEX12 Operating Instructions For The User Download Page 6

DEX ELECTRONIC MPS®

6

3. How to use

•  Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use 

abrasive or chlorine-based cleaning agents or solvents.

•  For a good water supply, the outlet fittings (special tap aerators and shower heads) 

should be unscrewed and cleaned at regular intervals. Every three years, the electri-
cal and plumbing components should be inspected by an authorised professional in 
order to ensure proper functioning and operational safety at all times.

Cleaning and maintenance

Repairs must only be carried out by 
authorised professionals.
If a fault in your appliance cannot be 
rectified with the aid of this table, 
please contact the service organisa-
tion of your importer or the Central 
Customer Service Department. Please 
have the details of the typeplate at 
hand.

Problem

Cause

Solution

Water stays cold, digital 
display does not light up

Master fuse tripped Renew or activate fuse
Safety pressure cut-
out tripped 

Contact customer service

Water stays cold, digital 
display does light up

Safety thermal cut-
out tripped 

Contact customer service

Display flashes error 
message “

Er

“ 

Control system has 
switched off

Switch fuse off and on. If “Er“ 
still flashes contact customer 
service

Flow rate of hot water too 
weak

Outlet fitting dirty 
or calcified

Clean shower head, jet 
regulator or sieves

Fine filter dirty or 
calcified

Let clean fine filter by customer 
service

Selected temperature is 
not reached , decimal point 
lights up

Water flow rate too 
high

Reduce water flow rate at the 
tap

Selected temp. is not 
reached , decimal point does 
not light

Cold water has been 
added via the tap

Tap hot water only; set 
temperature for use

Decimal point flashes

Inlet temperature 
exceeding nominal 
temperature 

Reduce inlet temperature

No response upon keypress

Hood is not fitted 
properly

Let refit the hood properly by 
customer service

4. Trouble-shooting and service

CLAGE GmbH

After-Sales Service
Pirolweg 1 – 5 
21337 Lüneburg 
Germany
Phone:  +49 4131 8901-40 
Fax: 

+49 4131 8901-41 

Email: [email protected]

This instantaneous water heater was manufactured conscientiously and checked sever-
al times before delivery. Should malfunctions nevertheless occur, it is usually only due 
to a bagatelle. First attempt to switch the house fuses off and on again in order to reset 
the electronics. Next, try to remedy the problem with reference to the following table. 
In doing so, you will avoid unnecessary expense of customer service assistance.

EHAB CENTER FOR  
IMPORT AND EXPORT

162 Omar Lotfy st 
Sporting 
21648 Alexandria 
Arab republic of Egypt.
Call us:  01277779272 
 15421

Al-Zamil Co. for Industry,  
Trade and Transport

2973 Imam Abdullah Bin Saud Bin Abdul 
Aziz Road Unit No.6  
Riyadh 13217 
P.O.BOX: 41397  
Kingdom of Saudi Arabia 
Phone:  +966 11 4620146 
Fax:   +966 11 456 9089 
Email: [email protected] 
www.zamilco.com

Nebraska Trading

Mr. Jalal Jaffer 
Block 704 Building 
2333 Road 439 
Salmabad, Block No. 704 
Manama – Bahrain
Phone:  +973 36347413 
Email: [email protected]

Summary of Contents for E-comfort DEX12

Page 1: ...Operating instructions for the user en 2 E convenience instant water heater DEX12 Subject to technical changes design changes and errors 9120 15027 12 20 9120 15027...

Page 2: ...he appliance is only suitable for domestic use and similar applications inside closed rooms and must only be used to heat incoming water from the mains supply The appliance must never be exposed to fr...

Page 3: ...ker with a contact opening gap of at least 3mm for each pole must be provided on the mains side of the connecting box for appliances with a fixed connection The wall bracket must be secured with the s...

Page 4: ...mitation cannot be exceeded Programme buttons The two programme buttons and allow to quickly select the preset temperature When pressing a programme key the preset temperature is selected and displaye...

Page 5: ...and instead enter a lower temperature on the appliance If you were to add cold water the water already heated would cool down again and valuable energy would be wasted Moreover the cold water added in...

Page 6: ...ustomer service Selected temperature is not reached decimal point lights up Water flow rate too high Reduce water flow rate at the tap Selected temp is not reached decimal point does not light Cold wa...

Page 7: ...15421 CLAGE GmbH Pirolweg 1 5 21337 L neburg 49 4131 8901 40 49 4131 8901 41 service clage de 13217 41397 966 11 4620146 966 11 456 9089 info zamilco com www zamilco com 704 439 2333 No 704 973 36347...

Page 8: ...DEX ELECTRONIC MPS 5 00 10 00 00 Reset 1 Press hold Reset completed 3 2 3 DEX LCD LCD 70 Unit provides no output Power limit 1 2 3 4 10 5...

Page 9: ...A1 A2 B1 B2 Store temperature 2 Press 3 sec Display of new value e g 43 C Set required temperature e g 43 C 4 3 1 3 Press 3 sec 1 2 Scalding protection off Confirmation of deactivation Scalding prote...

Page 10: ...DEX ELECTRONIC MPS 3 DEX 12 55 20 1 3 VDE 0700 2...

Page 11: ...CLAGE 2 2 1 3 3 2 4 3 4 4 4 5 5 5 5 5 6 6 4 1 43 8 www clage com downloads...

Page 12: ...12 20 DEX12 2...

Reviews: