clage E-comfort DEX12 Operating Instructions For The User Download Page 3

CLAGE 

3

The instantaneous water heater DEX 12 is a electronically controlled, pressure-resistant 
water heater for a decentralised water supply to one or more tap connections.
Its electronic control regulates the power consumption depending on the selected out-
let temperature, the respective inlet temperature and the flow rate, thus reaching the 
set temperature exactly to the degree and keeping it constant in case of pressure fluc-
tuations. The required outlet temperature can be entered on a keypad within a range 
between 20 °C and 55 °C and can be read off the digital display.

2. Description of appliance

not play with the appliance. Cleaning and user maintenance shall not be performed by children without 
supervision.

•  If the appliance is factory equipped with a connection cable, it must be replaced with an original spare cable 

from the manufacturer in case of damage by an authorised technician in order to avoid any hazards.

•  In accordance with VDE 0700, a circuit breaker with a contact opening gap of at least 3 mm for each pole 

must be provided on the mains side of the connecting box for appliances with a fixed connection.

•  The wall bracket must be secured with the supplied screws and dowels. The appliance must be secured to 

the wall bracket. The appliance may only be operated if it has been properly mounted on the wall bracket.

•  The prescribed nominal pressure stated on the rating plate may not be exceeded at any time.
•  The required water resistance may not fall below the value stated on the rating plate at any time.

To observe additionally for pressureless installation:

•  The water outlet behind the devices must not be blocked, and the water flow must not be restricted.
•  The water outlet facilities, such as shower head, jet control and other outlet unit, must be decalcified regu-

larly. Deposits must be removed in regular intervals.

•  Only the fittings recommended by the manufacturer may be used.
•  If the appliance is exclusive connected to a single shower, only the shower heads recommended by the 

manufacturer may be used. No other fittings or appliances which decrease the water flow to the shower 
may be installed.

1. Safety instructions

Summary of Contents for E-comfort DEX12

Page 1: ...Operating instructions for the user en 2 E convenience instant water heater DEX12 Subject to technical changes design changes and errors 9120 15027 12 20 9120 15027...

Page 2: ...he appliance is only suitable for domestic use and similar applications inside closed rooms and must only be used to heat incoming water from the mains supply The appliance must never be exposed to fr...

Page 3: ...ker with a contact opening gap of at least 3mm for each pole must be provided on the mains side of the connecting box for appliances with a fixed connection The wall bracket must be secured with the s...

Page 4: ...mitation cannot be exceeded Programme buttons The two programme buttons and allow to quickly select the preset temperature When pressing a programme key the preset temperature is selected and displaye...

Page 5: ...and instead enter a lower temperature on the appliance If you were to add cold water the water already heated would cool down again and valuable energy would be wasted Moreover the cold water added in...

Page 6: ...ustomer service Selected temperature is not reached decimal point lights up Water flow rate too high Reduce water flow rate at the tap Selected temp is not reached decimal point does not light Cold wa...

Page 7: ...15421 CLAGE GmbH Pirolweg 1 5 21337 L neburg 49 4131 8901 40 49 4131 8901 41 service clage de 13217 41397 966 11 4620146 966 11 456 9089 info zamilco com www zamilco com 704 439 2333 No 704 973 36347...

Page 8: ...DEX ELECTRONIC MPS 5 00 10 00 00 Reset 1 Press hold Reset completed 3 2 3 DEX LCD LCD 70 Unit provides no output Power limit 1 2 3 4 10 5...

Page 9: ...A1 A2 B1 B2 Store temperature 2 Press 3 sec Display of new value e g 43 C Set required temperature e g 43 C 4 3 1 3 Press 3 sec 1 2 Scalding protection off Confirmation of deactivation Scalding prote...

Page 10: ...DEX ELECTRONIC MPS 3 DEX 12 55 20 1 3 VDE 0700 2...

Page 11: ...CLAGE 2 2 1 3 3 2 4 3 4 4 4 5 5 5 5 5 6 6 4 1 43 8 www clage com downloads...

Page 12: ...12 20 DEX12 2...