8. Initial operation
In case the appliance will be commis sioned again under different installation condi-
tions than during its initial ope ration, it may be necessary to adapt the maximum
power rating.
A temporary short-circuit of the two pins, e.g. with a screwdriver acc. to EN 60900 (see
figure), will reset all heater parameters to works setting and lock the heating. Value
“21“ flashes in the display until the maximum power rating has been selected. This
condition will maintain when activating and deactivating the supply voltage.
Reinstallation
Lock level
The operating mode of the appliance can be restricted.
Activation of the Lock level
1. Disconnect the appliance from the power supply (e.g. by switching off
the fuses)
2. Insert the jumper on the power electronics (see picture)
3. Put the appliance into operation again
Deactivation of the Lock level
1. Disconnect the appliance from the power supply (e.g. by switching off the fuses)
2. Remove jumper
3. Put the appliance into operation again