3. Technical data
Model
CEX-U
Part no.
27921 - 50 °C model
27920 - 60 °C model
Energy efficiency class
A *
)
Rated capacity (Rated current)
11 / 13,5 kW (16 / 19,5 A)
Chosen capacity (Chosen current)
11 kW (16 A)
13,5 kW (19,5 A)
11 kW (16 A)
13,5 kW (19,5 A)
Electrical connection
3~ / PE 380..415 V AC
Min. required cable size
see note 1)
Hot water (l/min)
max. at ∆t = 33 K
4,8
5,8
2)
4,8
5,8
2)
Rated volume
0,3 l
Rated pressure
1.0 MPa (10 bar)
Connecting type
pressure resistant / pressureless
Heating system
Bare wire heating system IES ®
Required spec. water resistance @ 15 °C
Spec. electrical conductivity
≥ 1000 Ωcm
≤ 100 mS/m
Inlet temperature
≤ 70 °C
Flow rate to switch on – max. flow rate
2,0 – 5,0 l/min
3)
Pressure loss
0,2 bar at 2,5 l/min 1,3 bar at 9,0 l/min
4)
Temperature choice
20 °C – 50 °C
20 °C – 60 °C
Water connection
G ⅜"
Weight (when filled w. water)
2,7 kg
VDE class of protection
I
Type of protection / safety
IP24
*) The declaration complies with the EU regulation No 812/2013
1) The cross sectional area of the connection cable must be in accordance with the power rating of the appliance and the specific requirements of AS/NZS 3000
2) Mixed water
3) Flow rate limited to achieve optimum temperature rise
4) Without flow regulator