background image

WS15P Parts and Service Manual 

Page 15 

Problem

Possible Cause

Solution

18. Err -1006, Err – 106, 

Err - 116 = MAV/ SEPS/ NHBP/ AUX MAV 

valve motor ran too long and unable to 

fi

 nd the 

proper park position

Motorized Alternating Valve = MAV

Separate Source = SEPS

No Hard Water Bypass = NHBP

Auxiliary MAV = AUX MAV

a. Control valve programmed for ALT A or b, 

nHbP, SEPS, or AUX MAV with out having a 
MAV or NHBP valve attached to operate that 
function

a. Press NEXT and REGEN buttons for 3 

seconds to resynchronize software with 
piston position or disconnect power supply 
from PC Board for 5 seconds and then 
reconnect. Then re-program valve to proper 
setting.

b. MAV/ NHBP motor wire not connected to PC 

Board

b. Connect MAV/ NHBP motor to PC Board 

two pin connection labeled DRIVE. Press 
NEXT and REGEN buttons for 3 seconds 
to resynchronize software with piston 
position or disconnect power supply from 
PC Board for 5 seconds and then reconnect.

c. MAV/ NHBP motor not fully engaged with 

reduction gears

c. Properly insert motor into casing, do not 

force into casing Press NEXT and REGEN 
buttons for 3 seconds to resynchronize 
software with piston position or disconnect 
power supply from PC Board for 5 seconds 
and then reconnect.

d. Foreign matter built up on piston and stack 

assemblies creating friction and drag enough to 
time out motor

d. Replace piston and stack assemblies. Press 

NEXT and REGEN buttons for 3 seconds 
to resynchronize software with piston 
position or disconnect power supply from 
PC Board for 5 seconds and then reconnect.

19. Err – 1007, Err – 107, 

Err - 117 = MAV/ SEPS/ NHBP/ AUX MAV 

valve motor ran too short (stalled) while looking 

for proper park position

Motorized Alternating Valve = MAV

Separate Source = SEPS

No Hard Water Bypass = NHBP

Auxiliary MAV = AUX MAV

 

a. Foreign material is lodged in MAV/ NHBP valve

a. Open up MAV/ NHBP valve and check 

piston and seal/ stack assembly for foreign 
material. Press NEXT and REGEN buttons 
for 3 seconds to resynchronize software 
with piston position or disconnect power 
supply from PC Board for 5 seconds and 
then reconnect.

b. Mechanical binding 

b. Check piston and seal/ stack assembly, check 

reduction gears, drive gear interface, and 
check MAV/ NHBP black drive pinion on 
motor for being jammed into motor body. 
Press NEXT and REGEN buttons for 3 
seconds to resynchronize software with 
piston position or disconnect power supply 
from PC Board for 5 seconds and then 
reconnect. 

Summary of Contents for WS15P

Page 1: ...ETROLEUM JELLY KEROSENE BENZENE GASOLINE ETC WILL DAMAGE PRODUCTS THAT CONTAIN O RINGS OR PLASTIC COMPONENTS EXPOSURE TO SUCH HYDROCARBONS MAY CAUSE THE PRODUCTS TO LEAK DO NOT USE CLACK CONTROL VALVE...

Page 2: ...Page 2 WS15P Parts and Service Manual...

Page 3: ...ral Specifications 4 Drive Cap Assembly Pistons Stack Assembly Main Body 5 Regenerant Components 6 Injectors 7 Injector Flow Graphs U S Units 8 Injector Flow Graphs Metric Units 9 Fitting Kits 10 Drai...

Page 4: ...gpm 15 psi drop 227 lpm 13 6 m3 h Backwash flow rate 43 gpm 25 psi drop 163 lpm 9 8 m3 h Meter Accuracy Flow Range 5 0 75 75 gpm 2 8 284 lpm Inlet Outlet 1 5 Male NPT or BSPT Drain line 1 Male Elbow N...

Page 5: ...19 O RING 347 1 8 V4400 NPT WS15P NPT BODY ASSEMBLY 1 V4400 BSPT WS15P BSPT BODY ASSEMBLY 9 V4430 01 WS15P FTG ASY QC TO NPT 1 set of 2 V4430 02 WS15P FTG ASY QC TO BSPT 10 V3641 O RING 225 FOR VALVE...

Page 6: ...15P Regenerant Components 1 Drawing No Order No Description Quantity 1 H4615 RETAINING CLIP 1 2 V3498 WS15 BRINE ELBOW ASY W RFC 1 3 V3195 01 REFILL PORT PLUG ASY 1 4 V4430 04NPT WS15P NPT DRAIN KIT 1...

Page 7: ...iameter1 Quantity 1 V3010 15B WS1 5 Injector Asy B Violet 12 1 V3010 15C WS1 5 Injector Asy C Red 13 V3010 15D WS1 5 Injector Asy D White 14 V3010 15E WS1 5 Injector Asy E Blue 16 V3010 15F WS1 5 Inje...

Page 8: ...5 2 2 5 3 20 40 60 80 100 120 Pressure psi Flow Rate gpm Total Slow Rinse Draw ORDER NO V3010 15E BLUE ORDER NO V3010 15B VIOLET ORDER NO V3010 15F YELLOW ORDER NO V3010 15G GREEN 0 5 1 1 5 2 2 5 3 2...

Page 9: ...200 300 400 500 600 700 800 900 Pressure kPa Flow Rate lpm Slow Rinse Total Draw 2 4 6 8 10 100 200 300 400 500 600 700 800 900 Pressure kPa Flow Rate lpm Total Slow Rinse Draw 2 4 6 8 10 100 200 300...

Page 10: ...ROL VALVE PRODUCT S ON WATER SUPPLIES THAT CONTAIN HYDROCARBONS SUCH AS KEROSENE BENZENE GASOLINE ETC Clack Order No V4430 01 Description WS15P QC to NPT Fitting Kit Drawing No Order No Description Qu...

Page 11: ...62 053 5 3 GPM Drain line flow control V3162 065 6 5 GPM Drain line flow control V3162 075 7 5 GPM Drain line flow control V3162 090 9 0 GPM Drain line flow control V3162 100 10 0 GPM Drain line flow...

Page 12: ...ce meter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted...

Page 13: ...water pressure water pressure must remain at minimum of 25 psi b Incorrect injector size b Replace injector with correct size for the application c Restricted drain line c Check drain line for restri...

Page 14: ...t c Loosen main drive gear Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect d Imprope...

Page 15: ...ze software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect d Foreign matter built up on piston and stack assemblies creating friction and drag enough to...

Page 16: ...Page 16 WS15P Parts and Service Manual...

Page 17: ...WS15P Parts and Service Manual Page 17...

Page 18: ...Page 18 WS15P Parts and Service Manual...

Page 19: ...oved V3190 series of DLFC from table and V3190 XXX drawing 7 6 2020 PAGE 11 All DLFC housings ship without DLFC installed Up to 5 x V3162 XXX DLFC may be installed in V4430 Select 1 5 flow controls fr...

Page 20: ...shall be limited at its option to replacement or repair of any Softener and Filter Control valve covered by this Limited Warranty Prior to returning a Control Valve OEM must obtain a return goods aut...

Reviews: