WS1.5", 2" and 2"QC Drawings and Service Manual
Page 11
1. After installation is completed, turn on the supply water to check for leaks
2. Fully open a cold water faucet downstream of the system
3. Allow water to run until clear
4. Close the cold water faucet
5. Turn off the supply water
6. The system is now ready for startup
Systems With A Regenerant Tank
1. Manually pour enough water into the regenerant tank to reach the top of the air check valve.
2. Press and hold the REGEN button for three seconds until the drive motor starts. Press the REGEN button to advance the unit to
the backwash cycle. Wait until the motor stops and the backwash time begins to count down.
3. Open the inlet water supply valve very slowly allowing water to
fi
ll the tank in order to expel air. CAUTION: If water
fl
ows too
rapidly, there will be a loss of media out of the drain.
4. When the water is
fl
owing steadily to the drain without the presence of air, press the REGEN button to advance the control to
brine position. Wait until the motor stops and the brine time begins to count down.
5. Fully open the water supply inlet valve. Check that water is being drawn from the regenerant tank & there should be a slow
fl
ow
to the drain. Allow three minutes for the media bed to settle.
6. Press the REGEN button to advance the unit to the rinse position. Allow water to run to drain for 2 - 3 minutes, or until the drain
runs clear.
7. Press the REGEN button to advance to the
fi
ll position. Allow water to run into the regenerant tank and prepare it for the next
regeneration. Allow the regenerant tank to
fi
ll automatically. Systems with a salt grid should see a water level 1 ½” - 2” above the
grid.
8. Add salt to the tank, and allow ample time to dissolve salt for the brine solution.
9. SANITIZE! Add a sanitizer to the regenerant tank brine well following dosage recommendations speci
fi
ed by the media manu-
facturer. Press and hold the REGEN button for three seconds to begin regeneration. Allow the system to complete the regenera-
tion automatically. The system will now be sanitized and producing treated water. Be sure to check for local codes which may
also specify sanitization methods.
Systems Without A Regenerant Tank
1. Press and hold the REGEN button for three seconds until the drive motor starts. Press the REGEN button to advance the unit to
the backwash cycle. Wait until the motor stops and the backwash time begins to count down.
2. Open the inlet water supply valve very slowly allowing water to
fi
ll the tank in order to expel air. CAUTION: If water
fl
ows too
rapidly, there will be a loss of media out of the drain.
3. When the water is
fl
owing steadily to the drain without the presence of air, fully open the water supply inlet valve.
4. Press the REGEN button again to advance to the rinse position and allow water to run to drain for 2 - 3 minutes or until the drain
runs clear.
5. Press the REGEN button to advance to the service position.
6. SANITIZE! Add a sanitizer to the media following dosage recommendations speci
fi
ed by the media manufacturer. Be sure to
check for local codes which may also specify sanitization methods.
System Startup
Summary of Contents for WS1.5
Page 2: ...Page 2 WS1 5 2 and 2 QC Drawings and Service Manual ...
Page 6: ...Page 6 WS1 5 2 and 2 QC Drawings and Service Manual WS1 5 Gen 2 ...
Page 7: ...WS1 5 2 and 2 QC Drawings and Service Manual Page 7 WS2 ...
Page 8: ...Page 8 WS1 5 2 and 2 QC Drawings and Service Manual WS2 QC ...
Page 50: ...Page 50 WS1 5 2 and 2 QC Drawings and Service Manual ...