340
00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
13 Maintenance
13.9 Hydraulic system
67089
13.9 Hydraulic system
86485
13.9.1 Checking the hydraulic system oil level
– Park the machine on level ground.
– Lower the feeder as far as possible.
– Lower the reel all the way.
– Swing in unloading auger tube.
– Observe the general warnings at the beginning of
the "Maintenance" chapter.
– Read the oil level on the gauge rod (1).
The oil must not be higher than the FULL mark (maxi-
mum) and must not drop below the SAFE mark
(minimum) on the oil dipstick.
– If necessary, refill with oil at (A).
86487
13.9.2 Changing the hydraulic system oil / oil
filter / fresh air filter element
DOMINATOR 150 / 140
– Park the machine on level ground.
– Lower the feeder as far as possible.
– Lower the reel all the way.
– Swing in unloading auger tube.
Caution!
Machine operation with unpermitted or pol-
luted lubricants.
Machine damage.
– Ensure a clean environment.
– Use suitable and clean tools.
– Use permitted lubricants.
– Lubricants must be free of pollution.
111
DOMINATOR 150 / 140
23377
112
DOMINATOR 130
23382
1
A
A
1