4. MAINTENANCE AND INSPECION
21
2020-02-24
4. MAINTENANCE AND INSPECION
WARNING
Do not touch electrical wiring connections (bare live parts) of actuators equipped with
solenoid valves, actuators equipped with switches, and other such actuators.
Do not touch live parts with bare hands.
An electric shock may occur.
Turn off the power, release the residual pressure and make sure that there is no residual
pressure before disassembling or inspecting the actuator.
CAUTION
Plan and perform daily and periodic inspections so that maintenance can be managed
properly.
If maintenance is not properly managed, the product's functions may deteriorate significantly and
this may lead to faults (such as short service life, damage, and malfunction) or accidents
.
4.1
Periodic Inspection
In order to use the product under optimum conditions, perform a periodic inspection every six months or
when the operation count reaches 5 hundred thousand times
[ Inspection item ]
• Actuation state
• Air leakage
• Looseness of screws and bolts
• Backlash in the finger
• Stroke abnormality
4.2
Maintenance of the product
Regularly grease the sliding section of the finger with lithium grease. Regular greasing can extend
• service life further.
Manufacturer
Model
THK
AFF grease
4.3
Maintenance of the circuit
• Discharge the drainage accumulated in the air filter periodically before it exceeds the specified line.
• Since foreign matters such as carbide (carbon or tar substance) from the compressor oil may
contaminate the circuit and cause an operation fault of the solenoid valve or the cylinder, be careful
when performing maintenance or inspection of the compressor.