9
PRO MODE
● The mode will change to RUN mode when the mode selection key is held down
during this setting process. However, changed items before holding down the mode
selection key have been set.
RUN mode
<PRO mode>
Press for
4 seconds
<Sub-display selection>
Display OFF
Unit display
No. display
Standard
<Display speed selection>
500ms
250ms
<Reset setting>
RUN mode
RUN mode
<Sub-display selection>
When “
” is set
When “
” is set
Change the displayed details with
Set pressure
range is displayed
on sub display.
Custom
display
1,000ms
Min.
Max.
<Displayed color relation selection>
Relating with
comparative
output 1
Relating with
comparative
output 2
<Eco mode setting>
OFF
Standard
Max.
Automatic
<Setting check code>
<Setting copy mode>
Copy sending
OFF
Copy sending
ON
Copy sending
ON-L
Copy ready
state
When “No. display” or “Custom display” is set in “Sub display selection.”
●
Standard type only
Setting item
Factory setting
Description
Sub-display selection
Changes the indication of the sub-display.
“
” : Displays nothing.
“
” : Presently selected pressure unit is displayed.
“
” : Desired No. can be shown.
“
” : Desired numbers, alphabets (some of them cannot be displayed)
and signs can be shown.
Display speed
selection
Changes the speed of the displayed pressure value on the main display.
value selection
Sets hysteresis of the EASY mode and the window comparator mode.
(8 steps)
Displayed color rela-
tion selection
(Standard type only)
The setting contents set at the displayed color setting in Menu setting mode
can be related with either comparative output 1 or comparative output 2.
Eco mode setting
Current consumption can be lowered.
“
” : Normal operation (ECO mode is off.)
“
” : If any key operation is not carried out for approx. 5 sec. in RUN
mode, the display becomes dark.
“
” : If any key operation is not carried out for approx. 5 sec. in RUN
mode, the display is turned off.
Press any key to temporarily show the normal indication.
Setting check code
Current setting contents can be checked. For codes. refer to “
Code table
”.
Setting copy mode
The setting of the master side sensor can be copied to the slave side sensors.
For details, refer to “
10
SETTING COPY FUNCTION
.”
“
” : The setting contents are copied.
“
” : The setting contents are copied, and the slave side sensor goes
into key-lock state.
Reset setting
Returns to default settings (factory settings).
By pressing dowun mode key when “
” mode, becomes default settings
(factory settings).
Code table
●
Main display (1st digit form left)
Code
1st digit
2nd digit
3rd digit
4th digit
Standard type
High-function type
Standard type
Comparative
output 1
output mode
N.O. / N.C.
selection
Comparative
output 2
output mode
N.O. / N.C.
selection
Analogue
voltage / cur-
rent output /
external input
Threshold
display
Displayed
color of the
main display
Displayed
color relation
EASY
N.O.
OFF
OFF
Analogue
voltage output
P-1, Lo-1
Red when ON
Comparative
output 1
N.C.
EASY
N.O.
Auto reference
Hi-1
Comparative
output 2
Hysteresis
N.O.
N.C.
Remote zero-
adjustment
P-2, Lo-2
Green when ON
Comparative
output 1
N.C.
Hysteresis
N.O.
Analogue
current output
Hi-2
Comparative
output 2
Window
comparator
N.O.
N.C.
-
ADJ.
Always red
Comparative
output 1
N.C.
Window
comparator
N.O.
-
-
Comparative
output 2
-
-
N.C.
-
-
Always green
Comparative
output 1
-
-
-
-
-
-
Comparative
output 2
●
Sub-display (5th digit from left)
Code
5th digit
6th digit
7th digit
8th digit
Response time
Unit selection
Display speed
Eco mode
2.5ms
MPa
250ms
OFF
5ms
kPa
500ms
Std
10ms
kgf/cm
2
1,000ms
Full
25ms
bar
-
-
50ms
psi
-
-
100ms
mmHg
-
-
250ms
inchHg
-
-
500ms
-
-
-
1,000ms
-
-
-
5,000ms
-
-
-
10
SETTING COPY FUNCTION
● This can copy the settings of the master side sensor to the slave side sensor.
● Be sure to use the setting copy function between the identical models.
This function cannot be used between different models.
● Only one sensor can be connected on slave side with a master side sensor for the
setting copy function.
Setting procedure
1.
Set the setting copy function of the master side sensor to “Copy sending ON” or
“Copy sending ON-L”, and then press the mode selection key so that the sensor is
in copy ready state. For details, refer to
<Setting copy mode>
in “
9
PRO MODE
”.
2.
Turn OFF the master side sensor.
3.
Connect the master side sensor with the slave side sensor as shown below.
(Brown) +V
+V (Brown)
(Black) Comparative output 1
Comparative output 1 (Black)
(White) Comparative output 2 (Note 1)
Master side sensor
Slave side sensor
Comparative output 2 (Note 1) (White)
(Blue) 0V
0V (Blue)
Power supply
Color code of cable
with connector
Notes: 1) For the high-function type, external input.
4.
Turn ON the master side sensor and the slave side sensor at the same time.
(Note 2) (Note 3)
5.
Set contents (16-bit coded) are shown in orange on the main display of the master
side sensor and the copying starts.
6.
The same code explained above is shown in green on the the main display of the
slave side sensor, and
“
”
is shown on the sub-display (When copying is com-
plete.)
7.
Turn OFF the power of the master side sensor and the slave side sensor and dis-
connect the wire.
* If copying the setting to another sensor repeatedly, follow steps
3
to
7
.
Notes: 2) Take care that if the power is not turned on at the same time, the setting contents may not be copied.
3) Note that when the power is on, pulse output is output to comparative output 1.
To cancel the setting copy mode of master side sensor
1.
Whilst the slave side sensor is disconnected, turn on the power of the master side
sensor.
2.
Press the mode selection key for approx. 2 seconds.