CKD PPX Series Instruction Manual Download Page 3

9

PRO MODE

 

● The  mode  will  change  to  RUN  mode  when  the  mode  selection  key  is  held  down 

during this setting process. However, changed items before holding down the mode 
selection key have been set. 

RUN mode

<PRO mode>

Press for 
4 seconds

<Sub-display selection>

Display OFF

Unit display

No. display

Standard

<Display speed selection>

500ms

250ms

<Reset setting>

RUN mode

RUN mode

<Sub-display selection>
When “ 

 ” is set

When “ 

 ” is set

Change the displayed details with

Set pressure 
range is displayed 
on sub display.

Custom 
display

1,000ms

Min.

Max.

<Displayed color relation selection>
Relating with 
comparative 
output 1

Relating with 
comparative 
output 2

<Eco mode setting>
OFF

Standard

Max.

Automatic

<Setting check code>

<Setting copy mode>
Copy sending 
OFF

Copy sending 
ON

Copy sending 
ON-L

Copy ready 
state

When “No. display” or “Custom display” is set in “Sub display selection.”

 

Standard type only

Setting item

Factory setting

Description

Sub-display selection

Changes the indication of the sub-display.
“ 

 ”  :  Displays nothing. 

“ 

 ”  :  Presently selected pressure unit is displayed. 

“ 

 ”  :  Desired No. can be shown. 

“ 

 ”  :  Desired numbers, alphabets (some of them cannot be displayed) 

and signs can be shown.

Display speed 
selection

Changes the speed of the displayed pressure value on the main display.

value selection

Sets hysteresis of the EASY mode and the window comparator mode.
(8 steps)

Displayed color rela-
tion selection
(Standard type only)

The setting contents set at the displayed color setting in Menu setting mode 
can be related with either comparative output 1 or comparative output 2.

Eco mode setting

Current consumption can be lowered.
“ 

 ”  :  Normal operation  (ECO mode is off.) 

“ 

 ”  :  If any key operation is not carried out for approx. 5 sec. in RUN 

mode, the display becomes dark. 

“ 

 ”  :  If any key operation is not carried out for approx. 5 sec. in RUN 

mode, the display is turned off.

Press any key to temporarily show the normal indication.

Setting check code

Current setting contents can be checked. For codes. refer to “

Code table

”.

Setting copy mode

The setting of the master side sensor can be copied to the slave side sensors. 
For details, refer to “

10

SETTING COPY FUNCTION

.”

“ 

 ”  :  The setting contents are copied. 

“ 

 ”  :  The setting contents are copied, and the slave side sensor goes 

into key-lock state.

Reset setting

Returns to default settings (factory settings).
By  pressing  dowun  mode  key  when  “ 

  ”  mode,  becomes  default  settings 

(factory settings).

Code table

 

Main display (1st digit form left)

Code

1st digit

2nd digit

3rd digit

4th digit

Standard type

High-function type

Standard type

Comparative
output 1 
output mode

N.O. / N.C. 
selection

Comparative
output 2 
output mode

N.O. / N.C. 
selection

Analogue 
voltage / cur-
rent output / 
external input

Threshold 
display

Displayed 
color of the 
main display

Displayed 
color relation

EASY

N.O.

OFF

OFF

Analogue 
voltage output

P-1, Lo-1

Red when ON

Comparative 
output 1

N.C.

EASY

N.O.

Auto reference

Hi-1

Comparative 
output 2

Hysteresis

N.O.

N.C.

Remote zero-
adjustment

P-2, Lo-2

Green when ON

Comparative 
output 1

N.C.

Hysteresis

N.O.

Analogue 
current output

Hi-2

Comparative 
output 2

Window
comparator

N.O.

N.C.

-

ADJ.

Always red

Comparative 
output 1

N.C.

Window
comparator

N.O.

-

-

Comparative 
output 2

-

-

N.C.

-

-

Always green

Comparative 
output 1

-

-

-

-

-

-

Comparative 
output 2

 

Sub-display (5th digit from left)

Code

5th digit

6th digit

7th digit

8th digit

Response time

Unit selection

Display speed

Eco mode

2.5ms

MPa

250ms

OFF

5ms

kPa

500ms

Std

10ms

kgf/cm

2

1,000ms

Full

25ms

bar

-

-

50ms

psi

-

-

100ms

mmHg

-

-

250ms

inchHg

-

-

500ms

-

-

-

1,000ms

-

-

-

5,000ms

-

-

-

10

SETTING COPY FUNCTION

 

● This can copy the settings of the master side sensor to the slave side sensor.

 

● Be sure to use the setting copy function between the identical models.

This function cannot be used between different models.

 

● Only one sensor can be connected on slave side with a master side sensor for the 

setting copy function.

Setting procedure

1. 

Set  the  setting  copy  function  of  the  master  side  sensor  to  “Copy  sending  ON”  or 
“Copy sending ON-L”, and then press the mode selection key so that the sensor is 
in copy ready state. For details, refer to 

<Setting copy mode>

 in “

9

PRO MODE

”.

2. 

Turn OFF the master side sensor.

3. 

Connect the master side sensor with the slave side sensor as shown below.

(Brown) +V

+V (Brown)

(Black) Comparative output 1

Comparative output 1 (Black)

(White) Comparative output 2 (Note 1)

Master side sensor

Slave side sensor

Comparative output 2 (Note 1) (White)

(Blue) 0V

0V (Blue)

Power supply

Color code of cable 
with connector

Notes: 1) For the high-function type, external input.

4. 

Turn ON the master side sensor and the slave side sensor at the same time.
(Note 2) (Note 3) 

5. 

Set contents (16-bit coded) are shown in orange on the main display of the master 
side sensor and the copying starts. 

6. 

The same code explained above is shown in green on the the main display of the 
slave side sensor, and 

“ 

 ”

 is shown on the sub-display (When copying is com-

plete.) 

7. 

Turn OFF the power of the master side sensor and the slave side sensor and dis-
connect the wire.

*  If copying the setting to another sensor repeatedly, follow steps 

3

 to 

7

Notes: 2) Take care that if the power is not turned on at the same time, the setting contents may not be copied.
 

3) Note that when the power is on, pulse output is output to comparative output 1.

To cancel the setting copy mode of master side sensor

1. 

Whilst the slave side sensor is disconnected, turn on the power of the master side 
sensor. 

2. 

Press the mode selection key for approx. 2 seconds. 

Reviews: