■ Cleaning procedure
1) Remove the O-ring from the cartridge fitting.
2) Please clean the orifice section of the cartridge fitting.
Note)Wipe off the internal orifice with air blow or a soft cloth.
If the orifice is scratched, it will not be able to detect normally.
■ Assembly procedure
1) Fit the O-ring into the orifice section.
2) Insert the cartridge fitting into the product body.
3) Please insert the pin all the way from the front of the product.
Note)After disassembly / cleaning, please re-set threshold value.
Push-in fitting for tubing
Orifice
O-ring