CKD EVD Series Manual Download Page 2

Digital electro pneumatic regulator

EVD-1000

    Port size: Rc1/4
    Flow rate: 400    /min.
    Pressure range: 500kpa
    Grease free flow path section

Large flow rate type

EVD-3000

    Port size: Rc1/4Rc3/8
    Flow rate: 1500    /min.
    Pressure range: 500kpa

EVD-1000

EVD-3000

Port size

Maximum flow rate

Pressure range

Input signal

Series

Output type

Page

1500

Digital electro pneumatic regulator variation

5

400

500

kpa

500

kpa

Analog

Analog

output

Parallel

Parallel

1

Rc1/4

Rc1/4

10bit

10bit

Rc3/8

Flow path material

Grease

free

Fluorine

grease

Vaseline

(Custom order)

42

User-friendly, outstanding installation performance

Environment-friendly design

No lead or polyvinyl chloride

All lead and polyvinyl chloride has been eliminated.

Energy saving

"Automatic power off" automatically turns off the digital 
display.

Material display

Materials are indicated on main components to facilitate 
recycling.

Realizing high-level functions with microcomputer

Error display function

Errors are displayed and reported with electric signals.

Zero/span adjustment function

Zero and span can be adjusted according to the usage 
methods

Direct memory function

External input signals are not required.
Secondary pressure is adjusted as desired with 
operation keys.

Switch output function

Switch outputs (built-in overcurrent protection) is 
possible by setting the upper/lower limit pressure

Linearity     0.3%

Hysteresis 0.5%

Response time 0.2sec

Highly precise high-response pressure control

The digital display shows control status at a glance.

3-digit output pressure display
Output status (switch output ON-OFF) is displayed in 
addition to error display.

Parallel input available 
as standard

Direct control is possible from the PLC.

Compact design is 25% smaller
 (CKD comparison)

The highly universal D-sub connector 
enables bidirectional connection.

The connection is rotated 90 degrees from top to side, 
enabling top or side connection to be selected based on use.

Modular design

Filters and regulators, such as the 
C1000 Series, are connectable.

Switch

output

Analog

output

NPN
PNP

Switch

output

Analog

output

NPN
PNP

3-digit numerical LED display

Output display

Digital indicator

Operation key

D sub-connector

Modular design

100

The easy-to-use highly functional compact EVD Series digital electropneumatic regulator 

features a variety of new functions including pressure display, error display, and direct memory.

Summary of Contents for EVD Series

Page 1: ...1 Digitalelectropneumaticregulator EVD series CC 764A Compact high function digital control New product...

Page 2: ...ge methods Direct memory function External input signals are not required Secondary pressure is adjusted as desired with operation keys Switch output function Switch outputs built in overcurrent prote...

Page 3: ...trol Air turbine speed control Fixing of lead frames etc Assembly of chips EVD Cylinder Solenoid valve Grindstone Motor Controller EVD Air turbine EVD Tip EVD Lead frame EVD EVD Tank Magnetic tape Air...

Page 4: ...uipment or applications coming into contact with beverage or food amusement equipment emergency shutoff circuits press machine brake circuits or for safeguard Use for applications where life or assets...

Page 5: ...d valve relay etc and remove noise where generated Keep wiring to the device separate from strong magnetic fields Connect wiring to the device with a shield wire Ground the shield wire on the power su...

Page 6: ...e Do not use a load exceeding the output rating Failure to observe this may result in output damage or fire Installation Adjustment Installation WARNING Connector pin and cables conductors color must...

Page 7: ...agent on pipe connections with a brush and check for air leaks Lock the D sub connector so that it does not move Fix the fixed bed with a tool etc when releasing the screw lock CAUTION Piping The opt...

Page 8: ...m that it is operating correctly This case is made of resin Do not use solvent alco hol or detergent when cleaning because resin could be damaged Wipe off dirt with a rag dampened in a diluted neutral...

Page 9: ...kPa 0 5 F S or less 0 3 F S or less 0 2 F S or less 0 3 F S or less 0 15 F S or less 0 07 F S or less 400 min 0 2sec or less loadless 98 m s2 or less 5 to 50 5 to 50 Rc1 4 Free 250g Power supply rever...

Page 10: ...nitrile rubber Aluminum alloy SUJ Special nitrile rubber and stainless steel Silicon rubber Brass and electroless nickeling Fluoro rubber Blank C1 C3 P1 P3 None Analog 9 conductor cable 1 m Analog 9 c...

Page 11: ...age 9 for cable option dimensions 1 6 3 5 3 5 44 36 30 56 64 4 4 4 4 27 36 27 1 6 44 22 8 3 5 4 full R 7 2 32 22 42 42 4 full R 5 17 5 4 4 30 5 51 36 27 10 48 6 OUT IN 42 100 21 107 18 27 36 5 3 EXH p...

Page 12: ...ure Input signal kPa 0 0 200 400 600 100 200 300 400 600 500 Control pressure Flow rate min Working pressure 0 7MPa Working pressure 0 7MPa kPa 0 0 100 200 300 400 100 200 300 400 600 500 Control pres...

Page 13: ...ting minimum width 1kPa 0 5 F S or less 0 3 F S or less 0 2 F S or less 0 3 F S or less 0 15 F S or less 0 07 F S or less 1500 min 0 2sec or less loadless 98m s2 or less 5 to 50 5 to 50 Rc1 4 Rc3 8 Fr...

Page 14: ...ess steel Special brass and nitrile rubber Special brass and nitrile rubber Brass Nitrile rubber Steel sheet 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Blank C1 C3 P1 P3 None Analog 9 coductor cable 1...

Page 15: ...tion dimensions Rc3 8 EXH port 6 6 30 50 24 38 32 24 38 87 71 53 2 12 1 6 8 4 5 32 36 5 61 5 24 38 24 38 7 26 36 50 7 22 2 3 8 4 5 50 4 full R 52 4 133 OUT 24 38 50 IN 25 7 140 78 25 8 2 M4 depth12 D...

Page 16: ...200 300 400 600 500 Control pressure kPa 0 0 1000 2000 3000 4000 100 200 300 400 600 500 Control pressure kPa 0 0 1000 2000 3000 4000 100 200 300 400 600 500 Control pressure kPa Flow rate min Flow ra...

Page 17: ...n 0 to 10 VDC Vacant Vacant Monitor output Output short circuit protection circuit 1 to 5 VDC Switch output NPN or PNP output Error output NPN or PNP output Power supply 0V Type of input Isolator colo...

Page 18: ...M E M O M E M O 10...

Page 19: ...15 power supply max 50mA Signal generator Load Load Output short circuit protection circuit Main circuit Signal generator Pin 5 power supply Pin 13 monitor output Pin 11 analog input Pin 14 error out...

Page 20: ...8 Pin 8 bit 7 Pin 7 bit 6 Pin 6 bit 5 Pin 4 bit 4 Pin 3 bit 3 Pin 2 bit 2 Pin 1 LSB bit 1 Pin 13 switch output Pin 14 error output Pin 15 power supply max 50mA max 50mA Load Load Main circuit Pin 5 p...

Page 21: ...and setting are confirmed When Mode 1 valid is selected F4 0 tolerable range setting L tolerable range setting H is alternately displayed When Mode 2 valid is selected F4 1 lower limit setting value...

Page 22: ...pan adjustment and the setting are confirmed Note This is invalid if preset or direct memory input is selected for F1 mode F4 switch output function Screen F4 display details Switch output validity an...

Page 23: ...n F1 After setting exits setting mode and returns to screen F1 After setting exits setting mode and returns to screen F1 To select analog input Default Changing parallel input signal selection Input t...

Page 24: ...After setting exits setting mode and returns to screen F2 To use with adjusted zero span 2 seconds and over Input the set value key Moves digit key Counts up value Input the set value key Moves digit...

Page 25: ...scriptions Setting specifications Set the target pressure Range 000 to 500 Minimum setting 1 kPa Range 000 to 500 Minimum setting 1 kPa Range 00 to 50 Minimum setting 1 Range 00 to 50 Minimum setting...

Page 26: ...e and turn power on again Check the regulator s input signal set the input signal within the rated range and turn power on again Check primary pressure supply pressure within the rating and turn power...

Page 27: ...0 3 5541 1468 FAX 60 0 3 5541 1533 JOHOR BAHRU OFFICE 116 118 Jalan Rosmerah 2 17 Taman Johor Jaya 81100 Johor Bahru Malaysia PHONE 60 0 7 352 9129 FAX 60 0 7 352 9144 MELAKA OFFICE No B 10 Ground Fl...

Reviews: