12
2.4 Piping
Basic circuit
2.4.1
In order to operate normally, follow the basic items below and make the circuit as shown below.
Piping
2.4.2
• Use pipes that are made of corrosion-resistant materials after the filter such as zinc-plated pipes, nylon
tubes, and rubber tubes.
• Use pipes with an effective cross-sectional area that allows the cylinder to achieve the predetermined
piston speed.
• Install the filter for removing rust, foreign matters, and drainage from the piping as close as possible to the
solenoid valve.
• Observe the effective thread length for the gas pipes.
In addition, chamfer the threaded end of the pipes by about a 1/2 pitch.
• Before connecting the pipes, flush (air blow) the interiors of the pipes to remove foreign matters and
cutting chips.
Double acting cylinder
Solenoid valve
(Direction switching valve)
Compressed air
Air Reg Pressure gauge
Silencer
Speed controller
Effective length
Chamfer