![CKD ECS2-G4-00-50G-49-L-T2YD-D-H Instruction Manual Download Page 13](http://html1.mh-extra.com/html/ckd/ecs2-g4-00-50g-49-l-t2yd-d-h/ecs2-g4-00-50g-49-l-t2yd-d-h_instruction-manual_2611698013.webp)
9
2.3 Mounting
Cylinder installation
2.3.1
• This product, use mounting hokes of four through holes, screws and flange provided in the main body part,
and install it vertically with bolts.
CAUTION
Do not apply rotational torque to the piston rod when attaching or detaching the clamp
lever.
If rotating torque is applied, internal parts may be deformed or damaged, resulting in
malfunctioning.
WARNING
When rotating, make sure that the clamp lever attached to the tip of the piston rod does not
interfere with external peripheral equipment.
This cylinder, the piston rod strokes while rotating 90 ° during operation.
If there is a danger that the rotating of the clamp lever may endanger the human body,
implement safety measures such as installing a protective cover around the clamp lever.
If fix the body and tightening
or loosening, torque is applied
to the piston rod, and internal
parts will be damaged
ピストンロッドを回転する部分
まで引き出し、レバーを固定し
て、ボルトを締め付けてくださ
い。
ピストンロッドを回転する部分
まで引き出し、レバーを固定し
て、ボルトを締め付けてくださ
い。
ピストンロッドを回転する部分
まで引き出し、レバーを固定し
て、ボルトを締め付けてくださ
い。
Pull the piston rod to the
position where it rotates.
When tightening or loosening,
fix the lever by the vice or
screw wrench.