background image

4

CK Worldwide, Inc.

WARRANTY:

CK Worldwide, inc. warrants the Flexible Purge Chamber against defects in
materials and workmanship for a period of one year from the date of purchase.
Should it become defective for such reason, the manufacturer will repair it
without charge, if it is returned to the manufacturer's factory, freight prepaid.
Prior to returning the equipment, written authorization, in the form of an RGA
number must be obtained prior to any returns for any reason.  This warranty does
not cover:(1)failure due to normal wear and tear;(2)damage by accident, improper
use, neglect, unauthorized repair or alteration;(3)any one other than the original
purchaser.  In any event, CK Worldwide, Inc. will only be responsible for its
products when used with accessory items manufactured by CK Worldwide, Inc.

This limited warranty is in lieu of all other warranties, expressed or   implied.
The manufacturer shall not be liable for any injury to persons, including death; or
loss or damage to any property, direct or consequential, including, but not limited
to loss of use, arising out of the use, or the inability to use, the product. The user
assumes all risk and liability whatsoever in connection with the use of this
product, and before doing so shall determine its suitability for its intended use,
and shall ascertain the proper method of using it.  This warranty gives you
specific legal rights, and you may have other rights which vary from state to state.

The patented CK Flexible Purge Chamber is used in the Gas Tungsten Arc
Welding (GTAW)/Tungsten Inert Gas (TIG) process to provide a completely inert
atmosphere for the welding of reactive metals such as titanium, molybdenum,
nickel-based and aluminum-based alloys, as well as non-reactive metals like
stainless steel.  Unique to this design is the ability to draw a vacuum around the
product to be welded which collapses the chamber, removing all atmospheric
gases.  The chamber is then filled through a perforated hose that covers the
circumference of the chamber.  This filling process allows the argon gas to expel
all atmospheric gases more effectively than traditional filling methods.  This
significantly reduces the time required to reach a totally inert atmosphere that is
suitable for welding and uses considerably less gas than the traditional rigid purge
chambers.

INTRODUCTION:

DESCRIPTION:

The Flexible Purge Chamber is designed to rest on a support device that is the
same diameter as the chamber's base.  When the unit is completely deflated, with
the chamber's walls draped over the sides of the support base, a vacuum is drawn
by either 1.) blowing compressed air through the external vacuum "Y" creating a
venturi capable of expelling the atmospheric air inside the chamber, or 2.)
installing an auxiliary vacuum pump.  Once a vacuum is performed the chamber is
then inflated at 35 cubic feet per hour (Excessive fill rates will cause turbulence
resulting in the mixing of the argon shielding gas with the air in the chamber
which extends the time it takes to obtain a completely inert atmosphere).  The
purpose is to displace any remaining atmospheric air out the exhaust port on the
top of the chamber using argon which is significantly heavier than air.  Parts can
then be welded in a totally inert atmosphere.

To remain competitive in the domestic and international markets, we are allowing
customers to provide their own welding table and other accessories to fit inside
the chamber.

Summary of Contents for PC2000-24-220V

Page 1: ...ckworldwide com ck ckworldwide com NOTE Theimportantsafeguardsandinstructionsappearingin thispamphletshouldbereadandunderstoodpriorto operatingyourequipment SafetyGuidelines Warranty Introduction Desc...

Page 2: ...health 1 Keep your head out of welding fumes 2 Use adequate ventilation in the work area to keep fumes and gases from your breathing zone and the general work area 3 If ventilation is inadequate use a...

Page 3: ...cal injury or death through fires or electrical shock 1 Always have qualified personnel perform the installation troubleshooting and maintenance work Do not perform any electrical work unless you are...

Page 4: ...as TIG process to provide a completely inert atmospherefortheweldingofreactivemetalssuchastitanium molybdenum nickel basedandaluminum basedalloys aswellasnon reactivemetalslike stainless steel Unique...

Page 5: ...ent 24 Base Contact factory for price and availability on other sizes Height Width Shipping Weight StandardSize CHECKLIST One 1 TransparentFlexiblePurgeChamberEnclosure Four 4 Neoprene Gloves Two 2 In...

Page 6: ...roundcable Unpackthechambercarefullytoavoidcracking scratchingortearing Placethe chamberonapreparedtabletop thesamediameterastheinnerbasering At thistimetheheatblanketshouldbeplacedontheplasticbaseins...

Page 7: ...inlet of the Y which creates a venturi effect extracting all of the remaining air in the chamber or 2 Electric Vacuum Pump Plug pump into 115VAC circuit leave on until all airisvacatedfromthechamber N...

Page 8: ...ommended spittingonstarts Lowerosionrate widecurrentrange no spitting consistent arc starts good stability Lowesterosionrate highestcurrentrange no spitting best DC arc starts best stability SHIELDGAS...