background image

08

According to the holes parameter of installation plate, punch holes in the wall 

and install pipe expanding. Make sure to punch holes in strict accordance with

the parameters to avoid of plate deformation and failure installation. There’re 

two choices to punch holes.

Screw expand tube

 

X4

Wall Mount

Flush Mount

Summary of Contents for CRYSTAL TOUCH CT5

Page 1: ...CRYSTAL TOUCH READER CT5 INSTALLATION GUIDE V1 0 1 www civintec com...

Page 2: ...no responsibility is assumed by CIVINTEC Global Co Ltd for its use or for any infringement of patents or other rights of third parties which may result from its use No license is granted by implicatio...

Page 3: ...01 Reader Introduction 1 2 3 5 Touch Screen Display Card Reading Area...

Page 4: ...SAM Slot BLE rmware upgrade interface Software upgrade interface Tamper alarm PIN interfaces Speaker RJ45 TCP IP port Buzzer 2 6 7 3 4 5 8 1...

Page 5: ...02 Reader model introduction Suitable models CT5 MT X CT5 MET X CT5 MXT X...

Page 6: ...consumption Indicator I O Port 9 30VDC Average 800mA 12VDC IP Protection Operation Temperature Operation Humidity Certi cation Installation CE approved Tamper switch IP65 outdoor indoor use 20 60 C 0...

Page 7: ...content CT5 Reader Installation plate wall mount or ush mount Tamper resistant key Screw Screw expand tube 8 PIN Connector 2 PIN Connector Fixing screw RJ45 connector No Items Picture Volume 1 1 1 4...

Page 8: ...05 Two kinds of installation plates for user s selection wall mount type or ush mount type 16 5 18 1 Wall Mount Flush Mount 7 4 165 14 9 6 8 Wall Mount Flush Mount...

Page 9: ...06 Ensure that the area behind the tamper switch bulb of the installation plate is at Make sure that the Tamper Alarm button is completely against the wall for correct tamper alarm functionality Screw...

Page 10: ...07 Unscrew the xing screw from reader and remove the installation plate from reader Ensure that the installation plate is xed in the correct direction the arrows pointing upwards...

Page 11: ...te punch holes in the wall and install pipe expanding Make sure to punch holes in strict accordance with the parameters to avoid of plate deformation and failure installation There re two choices to p...

Page 12: ...e two holes on installation plate the upper hole is used for TCP IP cable and the second lower hole is used for connector wires Thread the cables through holes before xing it on the wall TCP IP Connec...

Page 13: ...re describes Make sure not to tighten the screws too hard as doing so will deform and skew the installation plate This may a ect the tamper switch functionality of the reader Screw Screw Screw Screw S...

Page 14: ...wire connection connect and x RJ45 connector to TCP IP cable which thread through upper hole RJ45 Connector 2 3 4 1 5 6 7 8 PIN TX TX RX unused unused RX unused unused Non POEPOE TX TX RX Power Power...

Page 15: ...12 Refer to CT5 reader PIN de nition connect the cables with 8Pin and fasten screws 8 PIN Connector...

Page 16: ...OUT IN OUT IN OUT IN OUT IN OUT Ground Power 5V 5V 5V 5V 5V 0V 9 30V 1 2 3 4 5 6 7 8 CT5 MX X T NO1 IO2 IO1 IO0 TR TR GND DC 9 10 11 12 13 14 15 16 NO2 D0 D1 D2 GND IN0 IN1 IN2 1 2 3 4 5 6 7 8 No Con...

Page 17: ...14 Insert the connectors into PIN on CT5 reader Make sure to place the connectors with the fastening screws facing towards you...

Page 18: ...rmly and make sure the bulge of key facing towards plate Tamper resistant key BULGE Note The bulge of wall mount and ush mount are di erent The height of bulge for wall mount is 14 70mm The height of...

Page 19: ...ule for data encryption In order to install the SAM into the reader open the SAM socket by unlocking and opening the lid Then place the SAM into the socket lock it into place by closing the lid and sl...

Page 20: ...areful not to press Touch screen directly Allign and t two sides of the top snap fastening as per the image above and hear a click sound Make sure it is tted correctly and maintain pressure on the top...

Reviews: