background image

 

The D3 Dimmer 

DMX Termination Switch

 

Figure 2, the D3 Dimmer 

 
The D3 Dimmer was designed to provide exceptional power and flexibility in a low 
voltage DC control unit.  The D3 Dimmer can be configured as three separate 10A 
dimmers, two 15A dimmers, or one 30A dimmer.  It will operate with any DC voltage 
between 9-12VDC.  Each dimmer channel can be separately configured with any of four 
different output profiles, including ICS curve dimming (for incandescent loads), linear 
dimming, LED dimming, or Non-Dim operation.    The unit may be configured either 
locally via the Button pad and LCD user interface, or via RDM. 
 

Controls, Connections and Features 
Front Panel 

LCD Display:  This 2 line by 16 character display shows all of the Menu titles, command 
options, configuration data, and other text and graphic data.  The backlight turns on 
whenever a button is pushed and turns off automatically after a preset time-out.  The 
backlight off time-out is adjustable via the Misc. Menu (see below).  
 
Control Button Pad:  This five-button pad is the main control interface 
for the D3 Dimmer.  The button functions are UP, DOWN, LEFT/BACK, 
RIGHT/FORWARD, and ENTER. 
 
During normal operation (default configuration), the Left, Down and Right Buttons serve 
as Bump Buttons for the three dimmers in the unit. 
 

Back Panel 

Anderson 45A Power Pole DC Power Input Connectors (Red +/Black -):  This is the 
+VDC power input for the D3 Dimmer, and mates directly with the 30A and 45A 
Anderson Power Pole connectors on the CTI # 5540 12V 12AH Batteries, CTI Anderson 
Twofers, cable assemblies, and other devices. The D3 Dimmer is capable of drawing up 
to 30 amps of DC power, so be sure that the connected input power wiring is up to the 
task! 

Be sure the power connection is polarized correctly

 before 

connecting an 

alternative supply.

  

 

5PXLRF for DMX/RDM Pass Thru

5PXLRM for DMX/RDM Input

1x2 45A Anderson PowerPole

for DCV Input

3x2 45A Anderson PowerPole

for Dimmer Outputs

Reset Switch

Control Button Pad

LCD Display

5620 SHoW DMX

er

5620 SHoW D

l Dimmer

 3 Channel DImm

Front View

MX 3 Channe

Back View

ENT

UP

DOWN

R

I

G

H

T

L

E

F

T

D3 Dimmer  

Back View 

D3 Dimmer  

Front View 

Page 5 

 

Summary of Contents for D3

Page 1: ...D3 Dimmer User s Manual Rev 4 2011 2013 City Theatrical Inc ...

Page 2: ...r Interface 4 The D3 Dimmer 5 Controls Connections and Features 5 Front Panel 5 Back Panel 5 Menu System 6 Menu 7 Addressing 7 Level Tests 7 Curve Selection 7 RDM Basics 7 Figures Figure 1 D3 Dimmer Front Panel 4 Figure 2 the D3 Dimmer Channel Dimmer 5 Figure 3 D3 Dimmer Menus 6 Page 2 ...

Page 3: ...The D3 Dimmer is intended for use only by qualified professionals Connection installation and hanging of this equipment must be performed in accordance with all pertinent local regional and national safety codes and regulations D3 Dimmer equipment is intended for indoor use only unless specified for outdoor use Keep the equipment dry Do not operate the equipment if it gets wet Do not operate in ex...

Page 4: ...PAD LCD DISPLAY ENT UP DOWN R I G H T L E F T Figure 1 D3 Dimmer Front Panel The D3 Dimmer User Interface Press the Enter center Button to access the menus and press the UP or Down Buttons to move through the menus When you reach a menu that you want to work in press Enter to select that menu and then use the UP or Down Buttons to move through that menu s options To scroll through a menu s selecti...

Page 5: ...nu see below Control Button Pad This five button pad is the main control interface for the D3 Dimmer The button functions are UP DOWN LEFT BACK RIGHT FORWARD and ENTER During normal operation default configuration the Left Down and Right Buttons serve as Bump Buttons for the three dimmers in the unit Back Panel Anderson 45A Power Pole DC Power Input Connectors Red Black This is the VDC power input...

Page 6: ...ess if required 5P XLR Male Connector DMX RDM Input Connect your DMX512 source here using any ESTA compliance DMX512 cable 5P XLR Female Connector DMX RDM Pass Thru Output When the Transmitter is connected to a conventional DMX controller this connector serves as a DMX pass thru DMX Termination Switch The D3 Dimmer DMX Input is provided with a conventional manual termination switch Switch the hand...

Page 7: ...by Default Battery Voltage Displays connected battery voltage RDM Label This is an editable field that allows the user to create a unique alpha numeric 16 character RDM label for the unit RDM Unique ID This is a non editable field that displays the RDM Unique ID Input Status Displays input status as DMX OK or DMX No Data Restore Defaults Restores factory defaults as DMX start 1 Triple Dimmer ISL C...

Page 8: ... its data link Once the controller has discovered all of the connected responders they can be monitored adjusted configured and generally managed individually over the RDM data link During normal RDM operations the Discovery process is periodically repeated so that added removed or failed devices can be identified and the controller s list can be updated There are a few caveats that should be unde...