4
•
In a single rack installation, attach a stabilizer to the rack.
•
In multiple rack installations, couple (attach) the racks together.
•
Always make sure the rack is stable before extending a component from the rack.
•
Extend only one component at a time, extending two or more simultaneously may cause the rack
to become unstable.
•
The handles on the left and right of the front panel of the appliance should only be used for
extending the appliance out of the rack. These handles should not be used for mounting the
appliance on the rack. Rack-rail hardware described earlier should be used instead.
Installing SFP Transceivers
The Citrix NetScaler 9010 SFP base system is shipped with four SFP (Small Form Factor Pluggable)
network ports. However, the actual number of modules you receive is dependent on the port configura-
tion purchased. Use the SFP transceivers only if you want to connect to the network using a fiber optic
cable.
Figure 4 illustrates the steps involved in installing the SFP transceivers into the appliance.
Figure 4
Installing SFP Transceivers
Warning
Only those SFP transceivers provided by Citrix Systems, Inc. are supported. Customers must not
attempt to install third-party SFP transceivers into the appliance as doing so will void the warranty.