Chapter 2 Nortel SIP Trunk Integration
11
Restarting the Signaling Server
Some fields in the CS 1000 Element Manager can be changed at run-time: SIP
domain name, CDS proxy (yes or no), Gateway username and password, dialing
plans, and all “SIP Service” related fields except ACD DN. The rest of the fields require
a restart of the Signaling Server.
To perform a warm restart
1.
From the EM Navigator, select
System > IP Network > Maintenance and
Reports
.
2.
Select the node containing the Signaling Server to be restarted.
3.
Click
Reset
for the Signaling Server.
To perform a cold restart
•
Press the
RST
button on the front panel to cold restart the Signaling Server.
Configuring the SIP Route and Trunks on the Call Server
The following topics describe how to configure the SIP route and trunks on the Call
Server using Nortel LD Overlays:
LD 97: “Defining a Virtual Superloop” on page 11
LD 17: “Creating a Virtual D-Channel” on page 12
LD 16: “Defining ISDN Support for a Customer ” on page 12
LD 15: “Creating a Virtual Service Route” on page 12
LD 14: “Creating Virtual Trunks” on page 13
Defining a Virtual Superloop
The following example shows how to define a virtual superloop using LD 97. For all
other fields not listed in the example, press
Enter
to use default values.
Prompt
Response
Description
REQ
CHG
Change existing data.
TYPE
SUPL
Superloop.
SUPL
V100
Create new virtual superloop 100.