Setting Up Connectivity
Connect the appliance to a management workstation or the network by using the
NetScaler configuration utility, the command-line interface (CLI), or the LCD keypad.
Configuration Utility Setup
To set up the appliance by using the configuration utility, you need a management
workstation or laptop configured on the same network as the appliance. To run the
configuration utility, the Java RunTime Environment (JRE) version 1.4.2_04 or later
must be installed on the workstation or laptop.
Note:
The Setup Wizard automatically opens upon log on when the appliance is
configured with the default IP address, when licenses are not installed on the
appliance, and when either the mapped IP address or subnet IP address is not
configured.
To configure the NetScaler by using the configuration utility
1. Connect the NetScaler to a management workstation or network.
2. Open a browser and type:
http://192.168.100.1
Note:
The NetScaler is preconfigured with the IP address 192.168.100.1.
3. In User Name, type
nsroot
.
4. In Password, type
nsroot
.
5. In the Setup Wizard, click Next and follow the instructions in the wizard.
6. To confirm that the NetScaler is configured correctly, you can either ping the new
NetScaler IP address (NSIP) or use the new NSIP to open the configuration utility in
a browser.
CLI Setup
To set up the appliance by using the command-line interface (CLI), connect the serial
cable to the console port. Access the command line with a terminal or terminal
emulator with the following settings:
w
Baud rate: 9600
w
Data bits: 8
w
Parity: None
w
Stop bits: 1
w
Flow control: None
Quick Installation and Configuration
8