Citizon CKG Operating Manua Download Page 3

CKG counting scales operation manual                                                                           

REV C1, June 2012 

                                                                              CKG counting scales operation manual 

CONTENTS 

1. Introduction…………………………………………….….…………..……1 

2. Key descriptions……………………….….…………………….…1 

3. Displays…………….………………………………………….…….2 

4. Basic operation……………………………….………………….…2 

4.1 Zeroing The Display………………………………………………….….2 

4.2 Taring…………………………………………………………………3 

4. 2.1 Norma l Ta re …………… …………… … ………… … …………3 

4 . 2 . 2   P r e ta r e … … … … … … … … … … … … … … … … … … … … … … 3 

5. Parts counting……………….………………………………….…4 

5.1 Setting unit weight………….……………………………………4 

5.1.1 Weighing a sample to determine the Unit Weight

…..……………….…..4 

5.1.2 Entering a Known Unit Weight……………..……………………...….5 

5.2 Parts counting……………..…………………...………...……………….5 

5.3 Automatic part weight updates………………………………….6 

6. weighing and counting checking alarm……………………….6 

6.1 set hi/low limit………………………………… ……………….6 

6 . 2   c h e c k i n g   a l a r m … … … … … … … … … … … … … … … . . 6 

7. Accumulated operation………………………………………..…6 

7.1 Manually accumulated total…………………………………….6 

7.2 Automatic accumulated totals…………………………………..7 

8

Calibration………………………………………………………………….7 

9 .   B a t t e r y   o p e r a t i o n … … … … … … … … … … … … … … … … … … . 8 

 

 

1. INTRODUCTION   

The CKG series of scales provides an accurate, fast and versatile 

series of counting scales. 

All units include automatic zero tracking, audible alarm for pre-set 

weights/quantity, tare, pre-set tare and an accumulation facility that 

allows the count to be stored and recalled as an accumulated total. 

 

2. KEY DESCRIPTIONS   

text symbol

function 

CE

 

Used to clear the unit weight or an erroneous entry. 
Hold this key can shift in weighing check alarm and 
counting check alarm. 

0~9 . 

Numeric entry keys, used to manually enter a value 
for tare weights, unit weight, and sample size. 

M+ 

 

Add the current count to the accumulator. Up to 99 
values or full capacity of the weight display can be 
added. 

MR 

 

To recall the accumulator memory. 

Pst 

 

To set the high/low limit for the weighing and 
counting checking alarm.   

Unit. wt. 

 

Used to enter the weight of a sample manually. 

Sample 

 

Used to input the number of items in a sample. 

Zero 

 

Set the zero point for all subsequent weighing. 
Display shows zero. 

Tare 

 

Tares the scale. Stores the current weight in 
memory as a tare value, subtracts the tare value 
from the weight and shows the Net weight. 
Entering a value using the keypad will store that 
value as the tare value. 

Print 

 

To print the results to a PC or printer using the 
optional RS-232 interface. 

 

 

 

 -1- 