When the watch has switched to the file error warning display, perform the garbage collection
procedure in the system monitor mode of the standard mode.  The display returns to normal
following completion of garbage collection. 

Abnormal Pressure Detection Error Warning

When abnormal atmosphere pressure is detected during use on land, or
when ascending to high locations more than 4000 m above sea level,
"ERR" (Error) flashes in the lower left corner of the display.  The watch
does not switch to the dive mode even if the water sensor gets wet
while this warning function is activated. 

If "ERR" does not disappear from the display even after a long period of time, there may be a
problem with the pressure sensor.  When this happens, discontinue using the watch and consult
a Citizen Consumer help desk or your nearest Customer Support Center. 

Water Sensor Check Warning

If the preliminary dive display continues to be displayed for more than 1
hour after the water sensor has gotten wet and the watch has switched
to the preliminary dive display in the dive mode, "CHK" (Check) flashes
in the lower left corner of the display to inform the wearer that the water
sensor should be checked. 

* "CHK" also flashes when the watch returns to the normal display from any of

the correction states, when the watch is returned to the time mode of the
standard mode from the infrared communication mode, and when the water
sensor is operating during the all reset procedure.

The watch does not switch to the dive mode (water depth measurement display) when "CHK" is
flashing.

To check the sensor, remove any debris or moisture from the water sensor with a dry cloth.  The
display returns to normal when the water sensor is canceled.

Ascent Rate Warning

When the ascent rate during scuba diving exceeds 18 m/min, the
ascent rate warning alarm sounds for 5 seconds and "SLOW" and an
illustration of a turtle are displayed at the bottom of the display.

The ascent rate warning alarm stops sounding when a proper ascent
rate is resumed.

* The ascent rate warning alarm does not sound during skin diving (continuous

diving for less than 3 minutes at a depth of 1 m or more).

Abnormal Depth Warning

When a sudden change in depth of more than 4 m/sec is detected
during diving, the watch assumes that the watch has reached an
abnormal depth.  At this time, "ERR" and the diver mark are alternately
displayed in the lower left corner of the display.

Once "ERR" has been displayed during diving, it continues to be
displayed until the dive mode is terminated. 

CAUTION

Avoid using the watch in environments where sea bottom drilling equipment or similar
machinery is in use.  The vibrations from such equipment may cause a change in water
pressure of "4 m or more per second" to be locally and momentarily applied to the pressure
sensor of the watch, causing "ERR" to be displayed and preventing water depth from being
displayed correctly.

W

Wa

arrn

niin

ng

g F

Fu

un

nc

cttiio

on

ns

s

This watch is equipped with various warning functions for the purpose of avoiding risks and
problems when diving as much as possible.  

WARNING

* Do not dive in a manner that activates any of the warning functions.  Since the degree of

risk varies according to experience, physical condition and diving conditions, do not
assume that diving is completely safe just because none of the warning functions are
activated.  Please use the warning functions as a general indicator of diving safety.  

Insufficient Charge Warning

When the watch becomes insufficiently charged, "BATT" flashes in the
lower left corner of the display in all of the sub-modes of the standard
mode.  Operation of the following functions is limited while this warning
function is activated.  
• The watch does not switch to the dive mode even if the water sensor

gets wet.  (The watch automatically switches to the battery charge
indicator display of the system monitor mode when the water sensor
gets wet.)

• None of the alarms sound.
• Data cannot be transferred by infrared communication.  (However, data can be transmitted to

a personal computer by USB communication.)

• The EL light is not illuminated.  

When this warning function is activated, charge the watch by attaching to the communication
unit as soon as possible.  The display will return to normal once the watch is sufficiently
charged.  

* None of the dive alarms sound when the insufficient charge warning function is activated during

diving.  Although the dive computer will function normally for about 30 minutes after "BATT" starts to
flash, the log data for that dive is not recorded.  Promptly begin to ascend it this warning function is
activated during diving.

* If the watch remains insufficiently charged after the insufficient charge warning function has been

activated, it switches to the low power mode after about 2 days.  Please note that if the watch
continues to be left uncharged in the low power mode, all functions stop and all watch settings return
to the initial (default) settings.

File Error Warning

When the amount of available memory in flash memory becomes low,
"FILE" flashes in the lower left corner of the display in all of the sub-
modes of the standard mode as well as in the dive mode.  The watch
automatically switches to the flash memory status display of the system
monitor mode when the water sensor gets wet while this warning function
is activated.  Please note that although it is possible to use the watch for
diving in this state, log data may not be recorded in flash memory during
diving.  
The file error warning function is also activated and additional log data is not recorded if the
duration of a single dive exceeds 2 hours or if more than 15 dives are made in a single day.  The
file error warning function may also be activated when the water temperature during diving is low.
It may not be possible to receive watch settings by data communication while the file error warning
function is activated.

108

109

Flashing

Flashing

Flashing

Flashing

Flashing

Summary of Contents for CYBER AQUALAND

Page 1: ...ltaneously pressing button A and button D for at least two seconds the watch returns to the normal display Refer to the section on Low power mode Temporally function in this manual for further informa...

Page 2: ...ta maximum depth dive time etc generated during diving as well as diving profile data and display that data in the form of log data By installing AQUALAND GRAPH 2001 in your personal computer from the...

Page 3: ...as described in this manual and strictly adhere to the procedures for its operation The watch may not function properly if handled in a manner not described in this manual This watch should not be us...

Page 4: ...Memory 137 Troubleshooting 138 Handling Precautions For the watch 140 Warranty and Service 142 Specifications 143 Please Direct Inquiries To 145 81 80 C CO ON NT TE EN NT TS S Introduction 76 Checking...

Page 5: ...y the batteries in the communication unit CAUTION The communication unit is not waterproof Do not allow it to come in contact with water or become wet In addition sand or dust inside the communication...

Page 6: ...charging is performed correctly in this case as well CHK is no longer displayed and the display returns to normal when the watch is removed from the communication unit after charging is completed If t...

Page 7: ...fresh water is actually 2 5 deeper than the displayed water depth Example Water depth displayed as 20 m x 1 025 20 5 m actual water depth C Ca au ut ti io on ns s R Re eg ga ar rd di in ng g U Us se e...

Page 8: ...urement of water depth begins automatically simply by placing the watch on your wrist and entering the water and various data depth elapsed time etc are measured automatically while diving This watch...

Page 9: ...main time that are the basic parameters of this watch This mode is normally displayed when wearing the watch 2 Travel Time Mode In this mode the watch displays the time and date for a different locati...

Page 10: ...phic representation of the amount of residual charge in the secondary battery and the changes in the battery charge indicator B Ba at tt te er ry y C Ch ha ar rg ge e I In nd di ic ca at to or r a an...

Page 11: ...n the surface mode has been activated The watch switches to the low power mode when buttons A and D are pressed for at least 2 seconds in the time mode of the standard mode If BATT ERR or CHK is flash...

Page 12: ...m by pressing either button B or button A Pressing button B advances the display by one step at a time while pressing button A moves the display back by one step at a time Pressing either button conti...

Page 13: ...o the newly set arrival time The remaining time is recalculated in the case the time or daylight savings time setting is corrected for the location set with the destination timer in the time mode or t...

Page 14: ...g The 12 hour or 24 hour format setting is in accordance with the setting in the time mode The watch automatically returns to the normal alarm display when none of the buttons are pressed for about 3...

Page 15: ...splay by pressing button D in the correction state display flashing 5 Chronograph Mode The chronograph function of this watch is able to measure time in 1 100 units for up to 99 hours 59 minutes and 5...

Page 16: ...se areas can be reused automatically Diving Function This indicates whether or not the watch can be used for diving When NG is displayed the watch will not switch to the dive mode The watch can theref...

Page 17: ...2 seconds during the flash memory status display During the garbage collection operation an alarm sounds and G C is displayed on the display When garbage collection is completed Done is displayed on...

Page 18: ...g displayed correctly W Wa ar rn ni in ng g F Fu un nc ct ti io on ns s This watch is equipped with various warning functions for the purpose of avoiding risks and problems when diving as much as poss...

Page 19: ...cending Time This refers to the minimum time required to ascend to the surface from the current depth in the case of ascending at the rate of 18 m min or less while making a decompression stop in acco...

Page 20: ...nables this to display the total number of scuba dives made throughout your life Dive Date This is the date year month and date on which a dive was made Dive Number This is the number of dives made in...

Reviews: