Be careful! Do not misconnect the wires or it will cause the air
conditioner can’t work normally, or cause fuses blown out or
other serious accidents.

The method of installation is as the diagram indicates, connect the power wires according to the
stipulated fixed colour and order.
a. Distinguish the colour, order and diameter of wires clearly while installation,the power wires
    between the indoor unit and the outdoor unit must be corresponding with each other, never
    be misconnected.
b. The yellow-green(     ) wire is the wire connecting to earth, it must be connected to the earth
    reliablly or it will cause electricity shock.
c. After installation, the wires must be pressed tightly with the wire clip, or it will cause
    serious accidents. Before press the wire, pull straight the wire, bind the remainder wire
    at the suitable place out of the unit to avoid being worn.
d. The screws of terminals must be screwed tightly, make sure they are firm by pulling the wires
    gently after screwing them.
e. Please add some connecting wires if the connecting wires are not long enough, the diameter
    of the wire must fit the stipulation and the colour must be the same.

4. Test Run

4-1 Pipe-cleaning and Taking Vacuum

Make sure all the pipe joints have been screwed tightly according to the fixed wring torque,then
engage in the pipe-cleaning and taking vacuum operation.
1. Remove the valve core copper caps of the high pressure valve and the low pressure valve.
2. Remove copper cap of refrigerant-adding valve, take vacuum with vacuum pump, and the \
    vacuum value should be less than 10Pa.
3. Fasten the copper cap of refrigerant-adding valve.
4. Loose the high pressure valve and low pressure valve all(anti-clockwise).
5. Use the leakage detector or soapy water to check the system pipe joint and valve cap for
    leakage.
6. If there is no leakage, cover the copper caps of valve cores(the must be screwed tightly).

3-5 Installation of the outdoor drain pipe

Insert the catchment trough into the hole of the base, connect an extended pipe to the trough.
Note: The drained water should not affect neighbours. (not available for the cooling type).

Base hole of the outdoor unit

catchment trough

Summary of Contents for CSRA-09

Page 1: ...nditioner Instruction Manual Thank you for purchasing of CITIZEN air conditioner To guarantee safety and best efficiency please read this manual carefully and keep a suitable storage for reference App...

Page 2: ...en the air conditioner is in using season detailed in inner pages Adopt the world famous compressor and micro computer controlling chip the performance is stable and reliable High efficiency compresso...

Page 3: ...Indoor Unit Remove Controller Wall mounted Plate Instruction Manual Certificate of Quality Guarantee Certificate Remote Controller s Brace Batteries AAA SIZE 1 5V Outdoor Unit Drain Hose Catchment Tr...

Page 4: ...nstall removed and reinstall the unit yourself Improper installation may cause leakage electric shock or fire Please engage an authorized dealer or specialist for the installation work Please use eart...

Page 5: ...t on the unit If abnormal conditions burnt smell etc occur please shut the power switch Do not use the unit for any other purpose Do not shut the power switch by drawing the cord Do not splash or dire...

Page 6: ...eration Contents Setting Operation of Timer Running Mode Air Direction Controlling Maintenance Method Operation Experience Guide Trouble Shooting Part Installation Instruction Select the Location for...

Page 7: ...d Functions 1 1 Indoor Unit 6 Outlet vent Intake vent Signal receiving window Air filter nets 2 CSRA 09 CSRA 12 Signal receiving window Indicator Iamps Outlet vent Intake vent Air filter nets 2 Indica...

Page 8: ...tdoor Unit CSRA 18 CSRA 18 Outlet vent Intake vent Outlet vent Intake vent CSRA 09 CSRA 12 Outlet vent Intake vent Signal receiving window Indicator Iamps Air filter nets 2 Auxiliary buckle 4 Emergenc...

Page 9: ...ared transmit tube Transmit signal to indoor unit Mode key Choose cooling dehumidifying heating Temperature setting key 16 J30 Wind speed key Choose Low Medium High Auto Air direction adjusting key Ti...

Page 10: ...uter automatically The remote controller transmit mid speed signal main frame will dispose it as low speed automatically The remote controller should be aimed at the receiving window of the main frame...

Page 11: ...erature buttons set the temperature you need Press SPEED button choose the fan speed you need Press DIRECTION button choose the air direction you want Stop press button Attention When it turns to the...

Page 12: ...t with soft cloth CAUTION Please regulate up and down air direction by remote controller Don t regulate the up and down air direction guide board with hand when the unit running or the link will be da...

Page 13: ...ce between indoor and outdoor should be within 5 or it will do harm to your health Try to reduce the invasion of outdoor heat open the doors or windows as few as possible avoid the direct sunlight try...

Page 14: ...low Repeatedly heat and defrost The compressor is at delay stage To protect the compressor there are several minutes delay for every start It has the function that can prevent the cold air from blowin...

Page 15: ...etres so does the height difference between them Avoid direct sunlight Exhaust water can be easily drained The air filter can be installed or removed easily There should be more than 20 cm space down...

Page 16: ...damaged it must be replaced by the manufacturer or its service agent or similar qualified persons in order to avoid hazard Medium power connecting wire Extended wire of socket Indoor unit Tie a thin c...

Page 17: ...on the installation plate fix the lower part with a hook 3 Installation of Outdoor Unit It should be installed on the rigid place Such as the concrete object If it was installed on the brick wall the...

Page 18: ...lted rugged Copper pipe Pipe cutter 2 remove burrs Get rid all the burrs of the pipes section Burr 3 install the nut Remove the connecting nut which is installed on the indoor unit and outdoor unit af...

Page 19: ...he back of the indoor unit if too thin it will cause dew and water dripping 3 3 Drain Hose For the convenience of draining off water please incline the drain hose downward when ar range it diagram 1 D...

Page 20: ...crewing them e Please add some connecting wires if the connecting wires are not long enough the diameter of the wire must fit the stipulation and the colour must be the same 4 Test Run 4 1 Pipe cleani...

Page 21: ...normal Does every indicating lamp light normally Does it drain smoothly 2 Outdoor unit Is there abnomal noise or vibration when it is running Do the noise wind and water caused affect the neighbours I...

Page 22: ...cuit Extra notice will not be given if there are changes of the data please take the nameplate on the machine as the standard Note 1 2 3 21 Data Model Item CSRA 09 Type Cooling Capacity Heating Capati...

Page 23: ...Serial No eb48603 Version 070808...

Reviews: