15
2. Installation of Indoor Unit
2-1 Fix the Wall-mounted Plate
Find a rigid parts of the wall (such as pillar etc.),install the plate at the same level,the plate
must be fixed horizontally,or it will result in the indoor unit dropping water and abnormal noise.
There should be more than 10cm space at the up,left and right sides while installing the indoor
unit.
Select the position of the wall-hole.
Use an aiguille to drill a hole with ø6.5 cm or so.
Insert the wall-through sheath into the hole.
2-2 Drill Hole in the Wall
2-3 Installation of the Power Source
Warning:
It is absolute wrong to cut the power wire open and connect the extended wire
of the socket at the open place, unsuitable connecting wires is one of the major
reasons to cause accidents.
If the power supply cord is damaged, it must be replaced by the manufacturer
or its service agent or similar qualified persons in order to avoid hazard.
Medium power connecting wire
Extended wire of socket
Indoor unit
Tie a thin cord in the hole
More than 10 cm
More than 10 cm
More than 10 cm
Installation plate
The level can be obtained easily by aligning the hanging
cord with the stripe of middle holes
There should be a separate circuit to connect the power supply socket should tally with the
stipulation, the polarity of the socket should match with the air conditioner.
The specification of the power wires and the connecting
wires should tally with the relative standards.
To connect power wires must strictly be in accordance
with the electric diagrams and connecting marks.Only
the same marks can be connected together.
The position of connecting power wires between indoor
unit and outdoor unit must be well selected and avoid
direct sunlight.
Wall hole
Thickness of wall
Wall-through
sheath
Indoor