49
—
—
3.4 Adjusting Media Sensor Positions
This section describes the procedure to adjust sensors when loading media. Transmis-
sive and reflective sensors can be used for the media sensors.
The printer comes from the factory equipped with a transmissive sensor. The media
sensor must be replaced with a reflective sensor for certain types of media.
Refer to 7.1 Sensor Adjustment Mode
Range of Paper Sensor Adjustment
The following figure illustrates the range of media sensor adjustment.
Left fixed media guide
118 mm (Max. media width)
(Moval scope of transport sensor)
6.0 to 26.0 mm
(Moval scope of reflective sensor)
6.0 to 74.0 mm
Dimension of
media feed
2.5 mm
Left margin
CL-E321:11.5 mm
CL-E331:10.5 mm
Right margin
CL-E321:104.0 mm
CL-E331:105.0 mm
Printable area
Summary of Contents for CL-E321
Page 1: ...LINE THERMAL PRINTER MODEL CL E321 CL E331 User s Manual...
Page 36: ...36 2 Open the top cover...
Page 37: ...37 3 Open the top ribbon cover...
Page 38: ...38 4 Open the bottom ribbon cover...
Page 43: ...43 9 Close the bottom ribbon cover...
Page 44: ...44 10 Close the top ribbon cover...
Page 94: ...94 External Dimensions 5 CL E321X NX standard model 266 172 8 178...
Page 95: ...95 CL E321X NS model with AC adapter storage case 266 214 8 178...