Citizen CH-671F Instruction Manual Download Page 14

- Eng 14 -

HOW TO WRAP THE WRIST CUFF

Wrap  the  wrist  cuff  around  your  wrist  properly.  Improper  wrapping
of the cuff may result in measuring errors.

1

Unfasten and open the wrist cuff.

2

Wrap  the  cuff  around  your  left
wrist  so  that  the  monitor  is
positioned  on  the  inside  of  your
wrist.

• Wrap the wrist cuff on bare skin.

• The wrist cuff is designed to fit wrists from

13.5 to 19.5 cm in circumference.

3

Loosely  fit  the  wrist  cuff  by
pulling the end of the cuff.

Summary of Contents for CH-671F

Page 1: ...Eng 1 REF CH 671F INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR English Espa ol Portugu s Deutsch 0801...

Page 2: ...regularly at the same time each day 8 DO NOT be too impressed by the results of one measurement Keep a record of blood pressure variations Many reading tell a story 9 Emotional stress may tend to caus...

Page 3: ...of blood pressure according to WHO standard Measure your blood pressure at the same time on a daily basis The blood pressure changes at all times This means that data gathered over a long period has g...

Page 4: ...a severe disorder of blood circulation in the arms Failure to do so may cause health hazards 8 Measurement may not be possible for someone with an insufficient blood flow in the area to be measured or...

Page 5: ...or a long period 4 DO NOT disassemble the apparatus 5 DO NOT bend the cuff or air hose unnecessarily 6 NEVER wipe the blood pressure monitor with thinner or benzene as they may damage it 7 When the mo...

Page 6: ...on EN60601 1 2 Name Address FLAT A B 4TH FLOOR HUNG MOU INDUSTRIAL BUILDING 62 HUNG TO ROAD KWUN TONG KOWLOON HONG KONG Manufacturer European Representative Name WvW elektronische Ger te Vertrieb GmbH...

Page 7: ...dopts a product shape and color that conveys an image of warmth and gentleness and has functions that cope with human body which are easy to understand safety in use and easy to use UNIVERSAL DESIGN M...

Page 8: ...correct match with positive and negative terminals The battery goes in negative side first 3 Re attach the battery box to the unit with the battery s visible side facing up Make sure not to depress th...

Page 9: ...life may be shorter than specified Dispose of used batteries properly in accordance with local regulations Replacing the batteries HOW TO UNLOAD BATTERIES HOW TO UNLOAD BATTERIES 1 Pull the battery bo...

Page 10: ...e been replaced the clock will indicate the time and date of the most recent measurement data in memory 1 After making sure that the power is turned off press and hold for more than a second The last...

Page 11: ...ng The digits representing the Date on the date display section will flash 4 Set the Date Press to set the current date Press This will finalize the Date setting The digits representing the Hour on th...

Page 12: ...inute on the time display section will flash 6 Set the Minute Press to set the current minute Press This will complete the clock setting procedure The device automatically turns off power The Second w...

Page 13: ...during measurement Wrap the wrist cuff properly T ake a deep breath and then relax before measuring blood pressure Lightly open your hand on the table with palm up and relax your fingers Fold up a tow...

Page 14: ...measuring errors 1 Unfasten and open the wrist cuff 2 Wrap the cuff around your left wrist so that the monitor is positioned on the inside of your wrist Wrap the wrist cuff on bare skin The wrist cuf...

Page 15: ...p edge of the cuff approximately 1 to 2 cm away from the crease of your wrist 5 Secure the wrist cuff with the Velcro If the wrist cuff is wrapped too loose or tight errors or incorrect readings may r...

Page 16: ...cuff around your left wrist See page 14 HOW TO WRAP THE WRIST CUFF Take a measurement so that the center of the unit is positioned over the artery located on your wrist If you have a weak pulse Positi...

Page 17: ...y 2 seconds The cuff will begin to inflate and the date and pressure readings will appear on the display Do not move your wrist or arm during inflation when measurement is in progress Do not press the...

Page 18: ...f Function HOW TO MEASURE YOUR BLOOD PRESSURE When a pulse is detected a pressure reading will shift to the diastolic pressure display section Once the pulse is detected the mark will flash with each...

Page 19: ...cannot be cleared individually 1 Press and hold for more than 2 seconds while the measurement results are displayed The message for memory clearance CL will appear and the device will automatically tu...

Page 20: ...d the data in memory cannot be recalled Measurements stored in memory are assigned a memory number in the order of measurement This means when 90 measurements are stored in memory the measurement havi...

Page 21: ...measurement will appear on the display The time and date appear alternately every 2 seconds When is pressed during display of data in memory its monthly average data will be called up 1 Press during...

Page 22: ...means when the current month changes from April to May the monthly average data of last May will be automatically erased If there is no monthly average data of the current month 0 zero will be shown...

Page 23: ...onth the month s most recent data in memory can be called up If such data are not stored in memory the display will remain unchanged HOW TO CALL UP PREVIOUS MONTHLYAVERAGE DATA 1 Press during display...

Page 24: ...r all memory data deletion ALL CL will appear on the display When the deletion process is complete the device shuts off automatically This step will permanently clear all data from memory Before proce...

Page 25: ...heart Blood pressure differs with age gender and other factors Blood pressure of one person is likely to be affected by biorhythm of a day posture physical activities mental activities stress and atm...

Page 26: ...home is reliable since it can be measured in a stable and relaxed condition Doctors lay importance on blood pressure measurements taken at home It is recommended to measure your blood pressure at the...

Page 27: ...rchased or your local service center See page 30 BEFORE ASKING FOR REPAIR INSPECTION Re wrap the wrist cuff properly Take deep breaths to relax and measure again See page 13 POINTS FOR ACCURATE MEASUR...

Page 28: ...digits Pulse 3 digits Date Time 4digit with AM PM mark Marks Measuring Battery mark LCD Viewing Size 34 5 H x 29 0 W mm Digit Size SYS DIA 9 4 H x 6 5 W mm Pulse 5 0 H x 3 5 W mm Switch 5 pcs Power Me...

Page 29: ...d during measurement Dimensions 80 5 H x 58 7 W x 23 5 T mm not including the wrist cuff Weight Approx 100g not including batteries Operating Environment Temperature 10 to 40 C Humidity 30 to 85 RH St...

Page 30: ...s Note that measurement of blood pressure may not be possible for someone with an extremely weak pulse or cardiac arrhythmia irregular pulses No measurement is possible If your blood pressure readings...

Page 31: ...O Japan CITIZEN es una marca registrada de Citizen Holdings CO Jap n Design and Specification are subject to change without notice 6 1 12 Tanashi cho Nishi Tokyo shi Tokyo 188 8511 Japan http www citi...

Reviews: