background image

Measuring method:

Indication:

Measuring range:

Accuracy:

Inflation:

Pressurization setting:

Deflation:

Exhaust:

Memory function:

Power source:

Battery life:

Rated voltage:

Working temp. & humidity:

Storage temp. & humidity:

Outside dimensions:

Weight:

Electric shock protection:

Accessories:

*Specifications may be changed without notice in the event of improvements being made.

SPECIFICATIONS

Oscillometric system

Digital display, Height: 19mm

Pressure; 0 

 280mmHg, Pulse; 40 

 200 beat/min.

Pressure; 

±

3mmHg, Pulse; 

±

5%

Automatic inflation by internal pump

4 stage: 160, 200, 240, 280mmHg

Automatic constant speed deflation system

Quick exhaust by electromagnetic valve

7 data

4 “AA” (R6P, LR6) batteries

Approx. 1000 times/LR6   Approx. 350 times/R6P

(once a day, 160mmHg, room temp. 22

°

C)

6V DC

+10

°

 +40

°

C, 30% 

 85%RH

–20

°

 +60

°

C, 10% 

 95%RH

111mm(W) 

×

 178mm(D) 

×

 73mm(H)

Approx. 470g (Apparatus batteries and cuff)

Type B equipment

Cuff, 4 “AA” (R6P) batteries, Instruction manual

Eng 2

 -

Summary of Contents for CH-611C

Page 1: ...OD PRESSURE MONITOR REF CH 611C TM English IDENTIFICATION OF PARTS Systolic blood pressure display section Diastolic blood pressure Pulse display section Memory reset switch Battery cover Air hose Hos...

Page 2: ...PECIFICATIONS Oscillometric system Digital display Height 19mm Pressure 0 280mmHg Pulse 40 200 beat min Pressure 3mmHg Pulse 5 Automatic inflation by internal pump 4 stage 160 200 240 280mmHg Automati...

Page 3: ...the same time each day Do NOT be impressed by the results of one measurement Keep a record of blood pressure variations Many readings tell a story Emotional stress may tend to cause pressure to rise F...

Page 4: ...s erased if the batteries are removed for replacement etc and a record should be kept of any necessary data Precautions for maintenance Do NOT store the blood pressure monitor where it will be exposed...

Page 5: ...le mentary Requirements for Electromechanical Blood Pressure Measur ing Systems Manufacturer Name Premier Precision Ltd Address Block E G H 6th floor Phase 2 Yip Fat Factory Building 73 75 Hoi Yuen Ro...

Page 6: ...of ready for measurement then the last pressure set ting value appears for approx 3 seconds Then the 0 appears at the display Ready for measurement 2 Attaching of wrist cuff Open the wrist cuff as the...

Page 7: ...level as your heart Relax your entire body especially from elbow to your finger 3 Select the value for pressure for measurement There are 4 settings 160 200 240 and 280mmHg After press on the Pressur...

Page 8: ...oves to the lower side of the dis play At this time the mark Q flashes and buzzer sounds When the diastolic pressure value is de tected the measurement is completed and buzzer sounds Systolic pressure...

Page 9: ...cond depressing of Memory Recall Switch the value for latest last measured value blood pressure is displayed mark flushes to notify that the value is the last measured newest one value Flushing By a t...

Page 10: ...n turns the power OFF after approximately 3 minutes To continue measurement press the power switch to turn the unit ON 10 Battery replacement If the batteries become weak the mark will appear in the d...

Page 11: ...e blood pressure could not be measured accurately Somenoise was detected or moved arm during measuring Repeat measurement again First exhaust air from the cuff reapply the cuff properly and remeasure...

Page 12: ...EN is a registered trademark of Citizen Watch Co Japan Consumer Electronics Division CBM Bldg 5F 5 68 10 Nakano Nakano ku Tokyo 164 0001 Japan Phone 03 5345 7430 Fax 03 5345 7431 E mail info con jcbm...

Reviews: