Citizen CH-462E Instruction Manual Download Page 14

- Eng 14 -

English

SETTING THE CLOCK

3

   Correcting the “minute” of an alarm time

•  Press “MODE” switch for one second or more to place the 

unit in the alarm-time minute correction state. 

•  Press “SET” switch to increase the minute of the alarm time 

in increments of one minute.

4

   Correcting the “hour” of an alarm time

•  After the completion of the alarm-time minute correction as 

described above, press “MODE” switch to place the unit in 
the alarm-time hour correction state.

•  Press “SET” switch to increase the hour of the alarm time in 

increments of one hour.

5

   Correcting the “second” of the current time

•  After the completion of the alarm-time hour correction as 

described above, press “MODE” switch to place the unit in 
the current-time second correction state.

•  Press “SET” switch to reset the second indication to 00. 

Press “SET” switch according to a time signal. Note that 
the minute indication on the display will advance when the 
seconds given is 30 to 59 seconds of a minute.

6

   Correcting the “minute” of the current time

•  After the completion of the current-time second correction as 

described above, press “MODE” switch to place the unit in 
the current-time minute correction state.

•  Press “SET” switch to increase the minute of the current time 

in increments of one minute.

Summary of Contents for CH-462E

Page 1: ...English INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH 462E 0801...

Page 2: ...CLOCK 17 MEASURING YOUR BLOOD PRESSURE 19 TIPS FOR OBTAINING ACCURATE MEASUREMENTS 23 AUTOMATIC CHANGEOVER FEATURE 23 HOW TO CALL UP THE VALUES STORED IN MEMORY TO THE DISPLAY 24 HOW TO CALL UP THE DA...

Page 3: ...a large number of readings 9 Emotional stress tends to cause your blood pressure to rise To obtain correct blood pressure measurements 1 Take ve or six deep breaths and then relax before measuring you...

Page 4: ...y be used as a guide in understanding non invasive blood pressure measurements The device is only intended for use with adults De nitions and Classi cations of Blood Pressure Levels Measure your blood...

Page 5: ...n in your arms consult your physician before using the monitor Failure to do so could be hazardous to your health 8 Measurement may not be possible for anyone with insuf cient blood ow to the area whe...

Page 6: ...onitor 5 DO NOT deform the cuff or bend the air hose excessively 6 If the monitor is very dirty wipe it clean with a cloth moistened with sterilizing alcohol or a neutral detergent Then wipe it with a...

Page 7: ...roducts in accordance with legislation under the WEEE Directive Directive 2002 96 EC and is effective only within European Union Reference European standard The blood pressure measuring device corresp...

Page 8: ...s that compliment the human body which make it easy to understand safe to use and easy to use UNIVERSAL DESIGN Large and Legible characters Simple and beautiful con guration Large and easy to press sw...

Page 9: ...Switch SET Switch Battery cover START STOP Switch a Stand by Cuff Air hose Date display Time display Battery icon Systolic blood pressure display Diastolic blood pressure display Pulse display Measure...

Page 10: ...batteries paying attention to the positive and negative terminal symbols m and 3 Close the battery compartment cover Battery compartment cover Lug projecting section Battery compartment 4 AA batteries...

Page 11: ...y power supply for the monitor unplugging the AC adapter will erase the data stored in the monitor s memory It is recommended that you make a note of any important data When only batteries are used to...

Page 12: ...ay not last as long as indicated Batteries included are for demonstration purposes only Battery life maybe shorter than speci ed When disposing of used batteries comply with governmental regulations o...

Page 13: ...f one Hold down the SET switch on to advance the setting continuously The aforementioned switch performance will not be carried out for the correction of 3 Second and 9 Time system 12 hour or 24 hour...

Page 14: ...ents of one hour 5 Correcting the second of the current time After the completion of the alarm time hour correction as described above press MODE switch to place the unit in the current time second co...

Page 15: ...correction state Press SET switch to increase the year of the current time in increments of one year The year can be set in the range of 2007 and 2036 9 Correcting the month After the completion of t...

Page 16: ...y to revert the display to the time indication This completes the clock setting procedure 12 How to set the alarm While the alarm symbol is shown on the display the alarm will sound for 30 seconds whe...

Page 17: ...LOOD PRESSURE The cuff should be put on the bare arm or over a light weight underwear If you wear a heavy weight top please remove it 2 Put the arm cuff around your arm so that the blue marker comes t...

Page 18: ...NG YOUR BLOOD PRESSURE 5 Place your arm on a table or the like so that the center of the cuff comes to the height of your heart Carefully place the cuff on your arm taking care to use the correct tigh...

Page 19: ...tly on the table so that your palm is facing up and your ngers are relaxed 4 Do not move your body or talk while taking the measurement Measurement in laying posture 1 Lie down your head facing the ce...

Page 20: ...r into the main unit Start measurement Plug the air hose connector rmly into the air hose socket on the main unit as illustrated Press the START STOP switch All of the segment will be displayed The ma...

Page 21: ...on display As long as the unit functions correctly the blood pressure and the pulse rate for the result with the record of the time and date are automatically stored in memory as one set of data Up to...

Page 22: ...htly on the cuff with the air hose connector inserted into the main unit Then put it in the cuff pocket Place the unit as a clock at such a location that you can observe the display easily 4 5 Manual...

Page 23: ...Except for the case where the unit is engaged in measurement press MEMORY switch to call up the values measurement results stored in memory to the display The value stored in memory is numbered in the...

Page 24: ...ata stored in memory appears on the display Press the MEMORY switch again This recalls and displays rst the memory number and then the last set of data stored Press the MEMORY switch again This recall...

Page 25: ...delete the data Then the buzzer sounds to let you know the completion of deletion of the data After the completion of data deletion the average value of the whole data stored in memory will appear on...

Page 26: ...Reapply cuff properly and measure again The pressure is 281 mmHg or higher If the pressure does not automatically decline during measurement immediately press the START STOP switch and turn the unit...

Page 27: ...rs when blood returns to the heart Systolic Diastolic Artery Artery Left atrium Left ventricle Left atrium Left ventricle Dilation The artery wall expands Contraction Normal state is restored to the a...

Page 28: ...our blood pressure is constant but it varies if you take measurements in repetition Blood pressure is susceptible to the time of day such as forenoon and afternoon season and atmospheric temperature I...

Page 29: ...batteries in the correct direction No measurements can be taken Check whether the measurement icon is displayed Attach the arm cuff properly Check whether the arm cuff is applied correctly Did you st...

Page 30: ...Rated voltage 6V 3W direct current Exhaust Electromagnetic quick exhaust valve Power supply 4 AA batteries LR6 or optional AC DC adapter 6V DC 0 6A Battery duration Alkaline Approx 500 times 170 mmHg...

Page 31: ...Design and Specification are subject to change without notice CITIZEN is a registered trademark of Citizen Holdings Co Japan CITIZEN es una marca registrada de Citizen Holdings Co Jap n...