HOW TO WRAP THE ARM CUFF

English

- Eng 12 -

HOW TO WRAP THE ARM CUFF

1

Unroll the arm cuff.

• When the arm cuff comes off, pass it

through metal bar, directing the
Velcro-attached side to the outer
surface.

2

Put the arm cuff around
your arm so that the air hose
comes to the left palm side.

• The arm cuff should be put on the

bare arm or over a light-weight
clothing. 

• If you wear a heavy-weight top,

remove it. Be aware that if you roll up
sleeves the upper arm may be
compressed resulting in incorrect
measurements. 

metal bar

Velcro

3

Adjust the arm cuff position as that the air hose is
located at the center of your arm and so that the
hem section of the cuff is spaced 1 to 2 cm from
the elbow joint.

air hose

4

Draw the end of the arm cuff
to fit it on the arm and
secure with Velcro.

• Carefully place the arm taking care to

obtain adequate tightness, not too
tight or loose. Adequate tightness is
obtained when you can place a finger
between the cuff and your arm. 

When you put the arm cuff around your right arm

You may measure your blood pressure on
your right arm. Adjust the arm cuff position
so that the air hose is located at the center
of your right arm exactly as shown in the
procedure for the left arm.
However blood pressure reading may differ
by about 10 mmHg between the right and
left arms. It is recommended to use the
same arm for measurement thereby
ensuring a consistent reading.

The air hose should be 
located at the center 
of your arm.

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Summary of Contents for CH-311B

Page 1: ...English Eng 1 INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH 311B English Espa ol Portugu s Deutsch an n 0801 Downloaded from www Manualslib com manuals search engine...

Page 2: ...inute as your arm will have built up higher blood pressure and you will not get valid reading 10 Next figure shows the classification of blood pressure according to WHO standard Measure your blood pre...

Page 3: ...d by the American National Standard Electronic or automated sphygmomanometers 19 Measurement of blood pressure may not be possible for someone with a common arrhythmias such as atrial or ventricular p...

Page 4: ...switch Pumping bulb Hole of holding strap OFF ON Air Hose socket Battery compartment cover Systolic blood pressure display section Diastolic blood pressure display section Pulse display section Englis...

Page 5: ...tery compartment cover 2 pull the cover toward you to open 2 Place the batteries in the compartment Fit the batteries paying attention to the positive and negative terminals 3 Close the battery compar...

Page 6: ...g out the portion from the elbow to the hand 2 It is important to have the arm cuff level to your heart 3 Lightly open your hand on the table with palm up and relax your fingers 4 Do not move your bod...

Page 7: ...en you put the arm cuff around your right arm You may measure your blood pressure on your right arm Adjust the arm cuff position so that the air hose is located at the center of your right arm exactly...

Page 8: ...ry function works on for approximately 2 second or during depressed the POWER switch After memorized blood pressure value is disappeared deflation mark appears If there is some air remaining in the cu...

Page 9: ...ER switch to turn off 4 5 Subsequent measurement For another measurement just pressurize the cuff by pumping bulb The time between two such Measurements must be at least 3 minutes Exhaust button Autom...

Page 10: ...e heart Blood pressure differs with age gender and other factors Blood pressure of one person is likely to be affected by biorhythm of a day posture physical activities mental activities stress and at...

Page 11: ...if the arm cuff is wrapped properly Did you stay calm during measurement Note that measurement of blood pressure may not be possible for someone with an extremely weak pulse or cardiac arrhythmia irr...

Page 12: ...English sure rent s ttery eries event of Downloaded from www Manualslib com manuals search engine...

Reviews: