background image

- Eng 11 -

POINTS FOR ACCURATE MEASUREMENT

English

- Eng 10 -

HOW TO UNLOAD THE BATTERIES

Replacing the batteries

• Replace the batteries with two new "AAA" batteries when 

appears on

the display, or when nothing appears on the display when the POWER
switch is pressed.

• The memory is erased if the batteries are removed for replacement, etc. and

a record should be kept of any necessary data.

• Do not use the alkaline dry battery and manganese dry battery together.

• The batteries provided with the unit power the monitor. They may not last as

long as indicated.

• Dispose of used batteries properly in accordance with local regulations.

Blood pressure varies with posture, the time of day or numerous
other factors. It is recommended to measure blood pressure at
the same time each day in the same posture.

Measurement in sitting posture

1

Place your arm on a table or similar
surface stretching out the portion
from the elbow to the hand.

2

It is important to have the arm cuff
level to your heart. 

3

Lightly open your hand on the table
with palm up and relax your fingers.

4

Do not move your body or talk during
measurement.

Measurement in laying posture

* Relax yourself not to apply 
  pressure to the arm cuff.

1

Lie down your head facing the ceiling.

2

Lightly open your hand with palm up and straighten your arm.

3

Relax your body, arm and fingers.

4

Do not move your body or talk during measurement.

1

Open the battery compartment
cover. 

(

See page 9 "HOW TO LOAD

BATTERIES".)

2

Remove the batteries.

3

Close the battery compartment
cover.

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Summary of Contents for CH-311B

Page 1: ...English Eng 1 INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH 311B English Espa ol Portugu s Deutsch an n 0801 Downloaded from www Manualslib com manuals search engine...

Page 2: ...inute as your arm will have built up higher blood pressure and you will not get valid reading 10 Next figure shows the classification of blood pressure according to WHO standard Measure your blood pre...

Page 3: ...d by the American National Standard Electronic or automated sphygmomanometers 19 Measurement of blood pressure may not be possible for someone with a common arrhythmias such as atrial or ventricular p...

Page 4: ...switch Pumping bulb Hole of holding strap OFF ON Air Hose socket Battery compartment cover Systolic blood pressure display section Diastolic blood pressure display section Pulse display section Englis...

Page 5: ...tery compartment cover 2 pull the cover toward you to open 2 Place the batteries in the compartment Fit the batteries paying attention to the positive and negative terminals 3 Close the battery compar...

Page 6: ...g out the portion from the elbow to the hand 2 It is important to have the arm cuff level to your heart 3 Lightly open your hand on the table with palm up and relax your fingers 4 Do not move your bod...

Page 7: ...en you put the arm cuff around your right arm You may measure your blood pressure on your right arm Adjust the arm cuff position so that the air hose is located at the center of your right arm exactly...

Page 8: ...ry function works on for approximately 2 second or during depressed the POWER switch After memorized blood pressure value is disappeared deflation mark appears If there is some air remaining in the cu...

Page 9: ...ER switch to turn off 4 5 Subsequent measurement For another measurement just pressurize the cuff by pumping bulb The time between two such Measurements must be at least 3 minutes Exhaust button Autom...

Page 10: ...e heart Blood pressure differs with age gender and other factors Blood pressure of one person is likely to be affected by biorhythm of a day posture physical activities mental activities stress and at...

Page 11: ...if the arm cuff is wrapped properly Did you stay calm during measurement Note that measurement of blood pressure may not be possible for someone with an extremely weak pulse or cardiac arrhythmia irr...

Page 12: ...English sure rent s ttery eries event of Downloaded from www Manualslib com manuals search engine...

Reviews: