CBM-270 User’s Manual
CITIZEN
85
GS C1 n1 n2 n3 n4 n5 n6
[Function]
Setting the numbering counter mode (A)
[Code]
<1D>H<43>H<31>H<n1><n2><n3><n4><n5><n6>
[Range]
0
£
n1, N2, N3, N4, N5, N6
£
255
[Outline]
This command sets the numbering (serial number counter) mode.
n1 + n2
´
256 (n1 = remainder, n2 = quotient) : Counter default
n3 + n4
´
256 (n3 = remainder, n4 = quotient) : Counter final value
n5
: Counter step value
n6
: Identical counter print count
(n1 + n2
´
256) < (n3 + n4
´
256)
: Count-up system
(n1 + n2
´
256) > (n3 + n4
´
256)
: Count-down system
(n1 + n2
´
256) = (n3 + n4
´
256) or n5 = 0 or n6 = 0 : Counter stop
[Default]
n1 + n2
´
256 = 1
n3 + n4
´
256 = 65535
n5 = 1
n6 = 1
[See Also]
GS C0, GS C2, GS c, GS C ;
[Sample Program]
LPRINT CHR$ (&H1D) ; "C0" ;
* CNT
LPRINT CHR$ (3) ; CHR$ (0) ;
FOR I=1 TO 6
LPRINT CHR$ (&H1D) ; "C1" ;
LPRINT CHR$ (&HID) ; "c" ;
LPRINT CHR$ (50) ; CHR$ (0) ;
NEXT I
LPRINT CHR$ (0) ; CHR$ (0) ;
LPRINT CHR$ (&HA) ;
LPRINT CHR$ (5) ; CHR$ (2) ;
RETURN
GOSUB * CNT
LPRINT CHR$ (&H1D) ; "C2" ;
LPRINT CHR$ (5) ; CHR$ (0) ;
GOSUB * CNT
END
[Print Result]
When setting a count-down range = 0 to 50, step
value = 5, repeat count = 2, and start value = 5 to
print a counter value.
When setting a count-down range = 0 to 50, step
value = 5, repeat count = 1, and start value = 50
to print a counter value. (The repeat count is