CBM-253 User’s Manual
11
CITIZEN
2.11 External appearance specifications
Weight Approximately
2.2kg
External dimensions Refer to 'External dimensions' at the end of this manual.
2.12 Environmental specifications
Temperature
Operating temperature
5°C~40°C
Storage temperature
-10°C~50°C (Excluding the recording paper)
Humidity
Operating humidity
35~80% (Non-condensing)
Storage humidity
30~90% (Non-condensing, excluding the recording paper)
2.13 Reliability specifications
Head lifetime
Pulse resistance
: 5
×
10
7
pulses
Wear
resistance
:
30
km
(At a printing rate of less than 25.0%, with a resistance value change rate of 15% or less.)
Cutter lifetime
500,000 cuts (At no paste of label on cutter blade.)
Please note that the above lifetime is not guaranteed value.
This value may change depending on installation environment of printer unit.
2.14 EMI standards and safety standards
FCC
Class A
VCCI
Type 1
UL
1950
EN
60950