background image

[Alarm Tone Monitor]
When button (A) is pressed with the crown in the
normal position in the alarm mode, the alarm tone
sounds for as long as button (A) is pressed.

[Stopping the Alarm Tone]
Press either button (A) or (B) to stop the alarm tone
while it is sounding.

14. All-Reset
This watch may not function properly as a result of
being subjected to the effects of static electricity or
strong impact and so forth. When this happens, set the
hands of the watch to their respective base positions
according to the following procedure after performing
the all-reset procedure.

When performing the all-reset procedure, first make
sure that the watch is fully charged and the second
hand is moving in one second increments. If the all-
reset procedure is performed when the watch is
insufficiently charged, it may not function properly or
remain stopped following the all-reset procedure.
1. Turn the crown to set the mode hand and the

chronograph [CHR] mode.

2. Pull out the crown to Position 2 (0 position correction

mode).
• Each of the hands and date wheel move to their

respective 0 positions stored in the memory and
then stop.

3. Press buttons (A) and (B) simultaneously and then

release.
• Following a confirmation tone, each of the hands

perform a demonstration movement in the order of
the function hand, 24 hour hand, hour hand, minute
hand and second hand to indicate that the all-reset
procedure is finished.

Note: Following the all-reset procedure, make sure to

properly reset each mode after performing 0-
position correction for each hand before using
the watch. The watch will remain stopped and
not run unless 0-position correction is performed.

15. Precautions

For correct use within the design limits of the watch, confirm the level of water
resistance of your watch, as indicated on the dial and case, and consult the table.

Summary of Contents for BL5XXX

Page 1: ...y battery is a clean energy battery that does not contain mercury or other toxic substances Once fully charged the watch will continue to run for about 9 months without additional charging when the power save feature is operating Power Save Feature When power generation stops as a result of light not shining on the solar cell during the time display or local time display the second hand stops at t...

Page 2: ...second interval movement However since the time is incorrect when the watch is exposed to light and changes to the insufficient charging warning display after it has stopped due to the insufficient charging set the time after sufficiently charging the watch Notes Chronograph measurement stops and the chronograph is reset even when measurement is in progress Set the time time difference is retained...

Page 3: ...ged and the overcharging prevention feature is operating the power save feature does not operate even when power generation is interrupted as a result of not exposing the solar cell to light Similarly the power save feature will also not operate when the secondary battery has temporarily become fully charged as a result of exposure to intense light 5 General Reference for Charging Times The time r...

Page 4: ...n the chronograph CHR mode to correct each hand 2 Pressing button A causes the second hand to be corrected by one second at a time each time it is pressed Continuously pressing button A causes the second hand to advance rapidly 3 Clicking the crown allows correction of the 24 hour hand hour hand and minute hand 1 Clicking the crown once to the right causes the hour and minute hands to move clockwi...

Page 5: ... year 0 min position 1 year after most recent leap year 6 min position 2 years after most recent leap year 12 min position 3 years after most recent leap year 18 min position 5 Pressing button B allows correction of the month Press button B and align the second hand at the position corresponding to the month 6 Return the crown to the normal position after setting the date The watch will resume kee...

Page 6: ...dnight during correction the date is advanced by one day following the completion of hand movement If the time difference is corrected in the counter clockwise direction and the hour hand passes back over 12 00 AM although the date is corrected following completion of hand movement since the date is corrected by 30 days in the clockwise direction it takes about 2 3 minutes for the date to be corre...

Page 7: ...t function properly or remain stopped following the all reset procedure 1 Turn the crown to set the mode hand and the chronograph CHR mode 2 Pull out the crown to Position 2 0 position correction mode Each of the hands and date wheel move to their respective 0 positions stored in the memory and then stop 3 Press buttons A and B simultaneously and then release Following a confirmation tone each of ...

Page 8: ...ccasionally Cleaning the Watch Use a soft cloth to wipe off dirt perspiration and water from the case and crystal Use a soft dry cloth to wipe off perspiration and dirt from the leather band To clean a metal plastic or rubber watchband wash away dirt with mild soap and water Use a soft brush to remove dust and dirt jammed in the gaps in the metal band If your watch is not water resistant take it t...

Page 9: ... hand Year display by function hand years elapsed from most recent leap year Additional functions Power save feature Time setting warning feature Insufficient charging warning feature Overcharging prevention feature Chronograph 60 minute measurement 1 20th second units Local time time difference correction 1 hour units Alarm 24 hour clock alarm monitor alarm ON OFF Continuous running times Fully c...

Reviews: