Regulatory
The EDAC meets the requirements of the EMC directive 89/336/EEC (CE Marking)
which include the standards for safety, emissions and immunity shown in Table 18.
Table 19. Regulatory Compliance
TEST
SPECIFICATION
PROCEDURE
Safety
UL 1459
Safety
CSA 22.2
Conducted Emissions, Powerline 230V
EN 55022:1994
CISPR 22, Class A;
FCC Part 15
Radiated Emissions, Electric 230V
EN 55022:1994
CISPR 22, Class A;
FCC Part 15
Electrostatic Discharge (ESD) Immunity
EN 50082-1:1992
IEC 801-2:1991
Radiated Immunity, Electric
EN 50082-1:1992
IEC 801-3:1984
(1988)
Electrically Fast Transient (EFT) Immunity
EN 50082-1:1992
IEC 801-4:1988
(1990)
Safety testing was completed in July 1994.
Emissions testing was completed in August 1994.
Emissions testing was repeated in August 1996 and December 1997.
Immunity testing was completed in August 1996.
Compliance applies to EDAC product revisions as shown below. Note that CE
compatibility applies only to later revisions for base units and port cards.
PART
SAFETY UL 1459 /
CSA 22.2
EMISSIONS EN
55022
IMMUNITY EN
50082
500-1090-001 Base
Unit
All Revisions
All Revisions
Revisions K or later
only
300-3030-001 Port
Card
All Revisions
All Revisions
Revisions M or later
only
300-3030-002 NE1
Port Card
All Revisions
All Revisions
All Revisions
300-3030-003
Aspect Port Card
All Revisions
All Revisions
All Revisions
VENDOR
TEST
RESULTS/REPORT
Lucent Technologies
System Interoperability
SIL Doc No. MY09-98