EDAC Installation Guide
512-1090-001, Revision K0
Page 42 of 56
Connecting Power
NOTE
Citel Technologies recommends the use of Uninterruptible Power Supplies or, at a
minimum, surge suppressors.
WARNING
Ferrite core end of the DIN power cable must connect to the EDAC to comply with
CISPR 22/
Wall Mount
1. Plug the 5-pin power supply connector from the power supply into the 5-pin
power input receptacle on the front of the EDAC unit. Refer to Figures 13-17.
2. Plug the power supply into a suitable AC power source.
Rack Mount/Wall Mount (Distributed Power)
1.
Connect one 5-pin power supply connector from one power supply to Power
Distribution Module input A and the other to input B. Refer to Figures 15-17.
2.
Connect DIN cables (P/N 450-1102-001) from module outputs to EDAC units as
needed. The ferrite core end must connect to the EDAC (see Figure 17).
3.
Connect the power supplies to a suitable AC power source.